  • Page 1 REFERENCE SERIES RD–101 REFERENCE DA CONVERTER OWNER’S MANUAL...
  • Page 2: Table Of Contents

    Maintenance Mains supply voltage Mains fuse Introduction Fuse type About this manual Replacing a blown fuse 24-25 Introduction to the Reference Series Firmware updating 26-27 1. Getting started 5. Warranty Unpacking the box, and how Warranty to correctly unpack it Heavy lifting –...
  • Page 3: From The Creator

    As a result of the above, our amplifiers do not “focus” on any specific frequencies - i.e. no extension of top or bass, At Vitus Audio everything works until proven not to. This way we which of course results in high clarity of the midrange since always try to push the limits and explore the unexplored.
  • Page 4: Introduction

    Introduction to the Reference Series This is your RD-101 owner’s manual. The following pages will, Reference Series is your entry point to the world of Vitus Audio. as clearly as possible, describe how to get your RD-101 operating The components in this series are cost-optimised versions of the quickly and easily.
  • Page 5: Getting Started

    1. GETTING STARTED 1. GETTING STARTED What’s in the box, and how RD-101 device overview to correctly unpack it Gently cut open the tape on the top of the box, making sure not Box contents let the knife protrude too much. Open the box and remove the INPUT MUTE MENU...
  • Page 6: The Topology Of The Volume Control

    1. GETTING STARTED 2. CONNECTING The topology of the volume control Turning the RD-101 on and off The topology of the volume control used in the RD-101 is very To prevent pop in the output, we have chosen to first add the new Always turn on the products beginning from the source: different compared to the “standard”.
  • Page 7: Connecting The Rd-101

    2. CONNECTING 2. CONNECTING Connecting the RD-101 The rear panel Place the RD-101 on its shelf. Connect all the sources to the inputs of the RD-101 labelled INPUT 1 to 5 on the rear panel. Connect the output of the RD-101 Lastly connect the mains to the DAC, after you have...
  • Page 8: Operation

    3. OPERATION 3. OPERATION Operation modes The RD-101 has 3 operation modes 1. NORMAL This is the mode you use when listening to music. 2. MENU In this mode you can alter the settings of the RD-101. 3. STANDBY In this mode the controls of the RD-101 are deactivated. 14 | RD-101 Owner’s manual RD-101 Owner’s manual | 15...
  • Page 9: Functions - Left Front Panel

    3. OPERATION 3. OPERATION Functions Functions – left front panel – right front panel INPUT   INPUT   MENU SELECT MUTE MENU SELECT MUTE STANDBY   STANDBY   Normal mode Menu mode Normal mode Menu mode In normal mode there are 3 basic functions/buttons available You enter menu mode, by pushing the “MENU”...
  • Page 10: The Elements In The Menu

    Change the brightness of the display to 0, 1, 2 or 3. TEXT Show the ID of the remote. are tested and approved by Vitus Audio). Lets you change the name of a specified input. UNPAIR By default the inputs are named input 1, input 2, etc. A list of INPUT NAME SETTINGS predefined input names can be found in the text-menu.
  • Page 11: The Rd-101 Menu Structure

    3. OPERATION 3. OPERATION The RD-101 menu structure MENU EXIT SETUP BACK EXIT VOL BP BP OFF / BP ON XLR OUT / RCA IN OUTPUT REMOTE BACK EXIT ENA REM REM ON / REM OFF REMOTE ID DATA o – 360 (min) AutoStb RESET RES.
  • Page 12: Operation And Service

    Mains fuse Fuse type: Vitus Audio products are designed to run for many years without Any unit may be set for operation in 100V, 115V or 230V/240V AC. The mains fuse is accessible from the outside of the amplifier. You Physical size - 20 x 5mm the need for regular maintenance.
  • Page 13: Replacing A Blown Fuse

    4. OPERATION AND SERVICE 4. OPERATION AND SERVICE Replacing a blown fuse Replacing a blown fuse REMOVE THE POWER CABLE The fuse carrier is placed on the back of the external Loosen the fuse carrier using a flat object like a flat screwdriver. Push the spare fuse out using a pointy object.
  • Page 14: Firmware Updating

    4. Plug the power chord into the RD-101. You can contact your local Vitus Audio dealer if you are uncertain 5. The display will show “new FT detected” while updating (this takes about 5 seconds).
  • Page 15: Warranty

    XLR Analog RCA Analog Audio or an authorised Vitus Audio repair center by the customer damage to chassis parts. (See 6) at his or her sole expense. Vitus Audio will pay return freight of Available 1 (L+R) 1 (L+R) 2. CONDITIONS its choice.
  • Page 16: Examples Operation

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Changing offset volume for inputs INPUT   MENU SELECT MUTE STANDBY   EXAMPLE 1 Changing offset volume for inputs A specific volume offset on the RD-101 can be set on each individual input, to accomodate for different output levels of different sources.
  • Page 17: Changing Display Brightness

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Changing display brightness Changing initial volume step INPUT INPUT     MUTE MUTE MENU SELECT MENU SELECT STANDBY   STANDBY   EXAMPLE 2 EXAMPLE 3 Changing display brightness Changing initial volume step The display on RD-101 can be set to different brightness levels You can set the volume step that the RD-101 will initialise on,...
  • Page 18: Disabling Inputs

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Disabling inputs Changing input names INPUT INPUT     MUTE MUTE MENU SELECT MENU SELECT STANDBY   STANDBY   EXAMPLE 4 EXAMPLE 5 Disabling inputs Example copy to be confirmed by client Each individual input on the RD-101 can be disabled in the menu.
  • Page 19: Setting Fixed Volume For Inputs

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Setting fixed volume for inputs Configuring auto standby INPUT INPUT     MUTE MUTE MENU SELECT MENU SELECT STANDBY   STANDBY   EXAMPLE 6 EXAMPLE 7 Setting fixed volume for inputs Configuring auto standby Each individual input on the RD-101 can be set to a fixed volume The RD-101 can be configured to automatically go into standby after...
  • Page 20: Restore Factory Settings

    7. EXAMPLES OF OPERATION 7. EXAMPLES OF OPERATION Restore factory settings INPUT   MUTE MENU SELECT STANDBY   EXAMPLE 8 Restore factory settings The RD-101 can be restored to it’s factory settings if needed. Press the “MENU” button to enter menu mode. YOU PRESS YOU SEE Use the function buttons on the front of the unit to navigate...
  • Page 21 HANDCRAFTED IN DENMARK AVA Group A/S (Vitus Audio) Hammershusvej 3H DK-7400 Herning Denmark Phone: +45 9626 8046 e-mail: sales@avagroup.nu Web: vitusaudio.com...

This manual is also suitable for:

Rd-101

Table of Contents