Download Print this page

Assa Abloy Corbin Russwin SN Series Installation Instructions Manual page 16

Advertisement

SN200/210 Integrated Wired
With and Without MELR Option (Electric Latch Retraction)
6B Inside Mounting Plate and Wire Connections (MELR)
1. Install the upper left mounting screw, #8 - 32 x 5/8 Fillister for metal door or #8 x 5/8 self-drilling
Fillister for wood doors (Figure 6f).
Note: Leave the screw loose enough to slide the MELR assembly on.
2. Snake the wire through opening in MELR assembly.
3. Slide the mounting clip of the MELR assembly underneath the installed screw and tighten it to secure
the assembly in place.
Note: Be careful not to pinch or disconnect the wire located in that area.
4. Install the remaining three (3) mounting screws: 8-32 x 5/8 Fillister for metal doors or #8 x 5/8
self-tapping Fillister for wood doors.
5. Connect 6- and 2-pin connectors from device to 6- and 2-pin connectors on reader harness
(Fig. 6b, c in previous step).
6. Connect ElectroLynx 4- and 8-pin connectors from the door harness to (black) 4- and 8-pin
connectors of the SN200/210 harness (Fig. 6d in previous step).
(4) #8-32 x 5/8"
Fig. 6f
Copyright © 2020-2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights
16
reserved. Reproduction in whole or in part without the express written permission of
ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Fig. 6F
Detail

Advertisement

loading

This manual is also suitable for:

Corbin russwin sn200 wiegandCorbin russwin sn210 osdp