Preamplifier; Rx Monitor; Swl (Bcl) Mode; Band Switching In The Swl Mode (Vfo Mode) - Kenwood TS-890S Instruction Manual

Hide thumbs Also See for TS-890S:
Table of Contents

Advertisement

5 COMMUNICATING AIDS

Preamplifier

The preamplifier can be configured to one of the two options: low
gain type that places priority on IMD (PRE 1) and high gain type
that places priority on sensitivity (PRE 2).
Press F [ANT/PRE].
Pressing F [ANT/PRE] each time switches the selection in the
following sequence: "PRE 1" → "PRE 2" → "OFF".
• The preamplifier selection is stored for each antenna
selection band.
• The default values are as follows.
Less than 7.5 MHz: OFF
7.5 MHz to less than 21.5 MHz: PRE 1
More than 21.5 MHz: PRE 2

RX Monitor

If weak signals are received while the squelch is closed, the signals
tend to be interrupted. Also, you may sometimes want to monitor
the condition of the RX frequency while in the CTCSS standby
state. In this case, the RX monitor is used to open the squelch
temporarily.
"RX Monitor" (Menu [0-15] to [0-31]) can be assigned to a PF key.
While the PF key that is assigned with "RX Monitor" is pressed and
held down, the squelch opens and the RX frequency can be
monitored. The RX monitor turns OFF once the key is released.
Scanning is paused while PF [RX Monitor] is pressed.

SWL (BCL) Mode

The SWL (BCL) mode is intended for SWL (Short Wave Listening)
and BCL (Broadcast Listening) by displaying the horizontal dial of
the "9R-59" communications receiver on the screen.
1 Press [MENU].
2 Press F [SWL] to display the SWL screen.
• If F [SWL] is not displayed, press F [MORE].
.
3 Press [MENU] followed by F [SWL].
Returns to the normal screen.
Switching to the SWL mode is not possible while the
transverter is ON.
An indicator is not displayed if a memory channel that is
not registered is being called up.
5-6
• Restrictions are applied to the following functions in the SWL
mode.
Function
Transmission
Disabled
Sending of voice message
Disabled
Decoding/Encoding
Disabled
Sending of CW message
Disabled
TX output power limiter
Disabled
Meter switching
Disabled
TX filter switching
Disabled
Turning ON transverter
Disabled
FM tone
Disabled
Antenna tuning
Disabled
Configuration of the TX
equalizer and related
Disabled
settings

Band Switching in the SWL Mode (VFO Mode)

Press F [BAND
]/ F [BAND
• The "broadcast/meter band" is displayed when the
frequency falls within the band range. The preset broadcast
bands are shown in the table below.
Broadcast/
Lower Limit
Upper Limit
Meter Band
[kHz]
LW
145
MW
525
120 m
2300
90 m
3200
60 m
4750
49 m
5900
41 m
7200
31 m
9400
25 m
11600
21 m
13570
19 m
15100
16 m
17480
15 m
18900
13 m
21450
11 m
25670
• The band segments of the SWL mode that is preconfigured on
this transceiver are represented in a slightly different way
compared to conventional meter bands. Different band
segments are used so as to achieve wider coverage to include
the broadcast bands of the different regions and other bands.
Status
].
Default [kHz]/ Mode
[kHz]
285
145
1705
525
2495
2300
3400
3200
5060
4750
6200
5900
7450
7200
9900
9400
12100
11600
13870
13570
15800
15100
17900
17480
19020
18900
21850
21450
26100
25670
AM

Advertisement

Table of Contents
loading

Table of Contents