MOD is displayed in an alternate display window so you
can see by how much you have exceeded it. In addition,
the Galileo 3 will beep incessantly. Both the blinking of
the depth value and the beeping will continue for as
long as you stay deeper than the MOD.
3 .7 .3

Absolute Minimum Depth (AMD)

Ascending above the AMD may lead to sudden loss of
consciousness and death by drowning.
If you are using a hypoxic gas mix, it produces a high
enough ppO
at greater depth, but at shallow depths
2
the Absolute Minimum Depth is reached and a message
MINIMUM DEPTH is shown. AMD value is shown in
the alternate display to indicate how much shallower
you have reached. In addition, the Galileo 3 will beep
incessantly. Both the blinking of the depth value and the
beeping will continue for as long as you stay shallower
than the AMD or switch gas.
3 .7 .4
CNS O
2
When the CNS O
2
toxicity. Start the procedure to end the dive.
The Galileo 3 tracks your oxygen uptake via the CNS O
clock. If the calculated value of CNS O
the Galileo 3 will emit a sequence of audible beeps for
12 seconds and the value of the CNS O
the O
window. The alarm will continue to be active until
2
the value of CNS O
GALILEO 3 USER MANUAL
WARNING
= 100%
WARNING
reaches 100% there is danger of oxygen
reaches 100%,
2
will turn red in
2
drops below 100%.
2
The audible signal is repeated for 5 seconds in 1-minute
intervals after the first occurrence, and for as long as
the value of CNS O
2
the ppO
drops under 0.5bar (see chapter Diving with
2
nitrox for a list of depths at which the ppO
0.5bar for typical nitrox mixes).
3 .7 .5

Tank reserve reached

See chapter Tank reserve to learn how to set the tank
reserve pressure limit. When this set pressure is reached
during the dive an alarm is triggered.
3 .7 .6

Missed decompression stop

Violating a mandatory decompression obligation may result
in severe injury or death.
If, when conducting a required decompression stop,
you ascend more than 0.5m/2ft above the required
stop, the Galileo 3 will trigger an alarm. The value of the
current depth and the message MISSED DECO STOP!
is shown and a sequence of beeps can be heard. This
will continue for as long as you stay 0.5m/2ft or more
above the required stop.
2
stays at or above 100% or until
2
WARNING
equals
69