Download Print this page

pdlux 30N2 Quick Start Manual

Infrared sensor

Advertisement

Quick Links

Infrared Sensor
Product size
80.5mm
48mm
Summary
The 30N2 product is a completely new concept design
with its output control section completely separated
from the sensor section. The bottom of the box can be
wired. It completely overcomes the problem of
traditional wiring connections. The sensor components
and control components use wireless connectivity
30N2
technology. The sensor section is completely separate
from the output control section and is extremely easy to
operate and easy to install. Fixed product only needs
two the screws make the installation of the sensor
simple. This is a completely revolutionary design. This
is our patented product.
The 30N2 uses a digital information processing
system. The easiest way to consider the 30N2 at the
start of the design is to remove the front frame of the
sensor and select the appropriate location for each
function to be replaced.
The 30N2 product can withstand a wide voltage of
100V-277V and can be used in any country in the
world. Standby power consumption <0.5W, powerful,
with dual control outputs, high power output can control
any load of 2300W, and the second output can control
any load of 1000W. There is also a 0-10V brightness
control port for controlling the brightness of the
dimming light. You can set the percentage of standby
brightness.
30N2 Considering the needs of different users, we
have reserved space for further expansion. Users are
welcome to ask about your needs. We are always
ready to add the features you need.
Please read the following sections of this manual
100mm
carefully for installation and operation.
Specifications
Power supply Voltage: 100-277V,50/60Hz
Main control:
Power: 2300W/230V
Auxiliary control:
Power: 1000W/230V
Dimming control: 0-10V 50mA
Delay: 10 sec-20 minutes (adjustable)
Detection Distance: 2-16m (radii.)/22°C.(adjustable)
Standby time: off / 10min/ 20min/ constant light
Standby brightness: 5%, 10%, 20%, 30%
Optical control Illumination: <10LUX~2000LUX
Detection angle: 360°
Mounting Height: 2.5m-4.5m
Max 3000W/230V
Max 1200W/230V
(adjustable)
Operating Temperature: -10 - +40°C
Probe movement speed: 0.6-1.5m/s
relative Humidity: <93%RH
Static power consumption:<0.5W
Feature Settings description
1. Sensitivity adjustment knob:
Sensitivity
adjustment
knob
is
managing the detection sensitivity of the system. The
user can select the position of the knob as needed to
adjust to the detection range you want. In general, the
sensitivity is just enough to detect the sensor within the
detection range, not too high, because too high prone
to misoperation. Adjust sensitivity with due regard to
ambient
temperature.
The
higher
temperature, the lower the detection sensitivity. The
manufacturer
recommends
that
temperature of 22°C to 24°C be used as a reference to
select the position of the sensitivity adjustment knob.
2. Delay adjustment knob:
The delay adjustment knob is responsible for
managing the load time after the sensor triggers the
work.
The knob can be set clockwise for a delay time of 10
seconds to 20 minutes. The user selects the
appropriate position of the knob according to needs.
3.LUX adjustment knob:
LUX setting knob is used by the system to detect the
ambient illumination, and it is the condition selection of
the sensor under the circumstance of which the user
chooses the ambient brightness that must be sensed.
When the knob goes counterclockwise to the bottom,
the sensor can only enter the induction when the
brightness of the installed position is lower than
10LUX, that is, the sensor can only work in the dark
hours at night. The higher the LUX value, the brighter
the ambient brightness. Users can set the appropriate
location according to their own needs.
4. D-TIME adjustment knob:
D-TIME knob is responsible for managing the
adjustment of the standby brightness of the sensor.
Knob clockwise direction can set 4 gears time. Users
responsible
for
the
ambient
the
ambient

Advertisement

loading

Summary of Contents for pdlux 30N2

  • Page 1 The 30N2 uses a digital information processing Feature Settings description system. The easiest way to consider the 30N2 at the start of the design is to remove the front frame of the 1. Sensitivity adjustment knob:...
  • Page 2 can set the appropriate location according to their own have continuous sensing function, in short, the sensor in needs. the delay time before the end of any induction, the 5.DIM setting knob: system will be re-timed, as long as the person in the DIM knob is responsible for managing standby detection range of activities, the lamp will not be brightness Settings.
  • Page 3 (3)DIM setting (3)Install the bottom Connection cover screw Bottom The brightness of standby gear four is: (such as ③) ; 1:5% Brightness 2:10% Brightness Installation is based on the wiring diagram provided. Connect 3:20% Brightness 4:30% Brightness power line and load When the knob is adjusted clockwise, line to the power TEST key: when the line is...
  • Page 4 the knob is counterclockwise to the end, illumination <10LUX to enter the inductive state. Delay Time Knob: refers to the lamp to receive the  inductive signal after the light to no subsequent induction signal, the lamp work stage value。 Some problem and solved way Load does not work:...