Advertisement

Quick Links

Instructions for use
PROPHYflex Perio Kit – 1.009.3731
Refill PROPHYflex perio tip – 1.010.0287

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROPHYflex 1.009.3731 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KaVo PROPHYflex 1.009.3731

  • Page 1 Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH KaVo Dental GmbH Bismarckring 39 Bismarckring 39 88400 Biberach 88400 Biberach Germany Germany Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 Table of contents Table of contents 1 User instructions ........................ 4 2 Safety..........................7 2.1 Infection hazard ......................7 2.2 Air embolism and skin emphysema ................. 7 2.3 Technical condition ......................
  • Page 4: User Instructions

    KaVo Dental GmbH. All other trademarks are property of their respective owners. KaVo Original Factory Repair In the event of a repair, please ship your product to the KaVo Original Factory Repair using www.kavobox.com. KaVo Technical Service If you have any questions or complaints, please contact the KaVo...
  • Page 5 Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 1 User instructions Thermodisinfectable Information on the packaging Material number Serial number Manufacturer Note: Please note accompanying documents Follow the electronic instructions for use HIBC Code CE mark for medical devices Medical device, labelling of medical devices Transportation and storage conditions...
  • Page 6 Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 1 User instructions CAUTION In cases which – if not prevented – can lead to minor or moderate in- jury. NOTICE In cases which – if not prevented – can lead to material damage. 6 / 24...
  • Page 7: Safety

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 2 Safety | 2.1 Infection hazard 2 Safety Note All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
  • Page 8: Technical Condition

    ▶ Both patient and user have to wear protective goggles during the treat- ment. ▶ KaVo recommends the use of dust extraction equipment and mouth protec- tion during the treatment with PROPHYflex. 8 / 24...
  • Page 9: Product Description

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 3 Product description | 3.1 Purpose – Intended use 3 Product description PROPHYflex Perio Kit – 1.009.3731 ① 1 x adaptor, ② 3 x perio tip, ③ 1 x wrench, ④ 1 x nozzle needle In addition, the PROPHYflex Perio Kit (Mat.
  • Page 10: Transportation And Storage Conditions

    Dispose of and recycle the packaging appropriately in accordance with current packaging law, employing waste management / recycling companies. Comply with the comprehensive return system. KaVo has had its packaging licensed for this purpose. Please comply with the regional public waste-disposal system.
  • Page 11: Startup And Shut Down

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 4 Startup and shut down | 4.1 Inserting the adaptor into the PROPHYflex 4 Startup and shut down WARNING Hazard from contaminated products. Infection hazard for care provider and patient. ▶...
  • Page 12: Removing The Prophyflex Perio Tip

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 4 Startup and shut down | 4.4 Removing the PROPHYflex perio tip Note In order to screw it on, hold the wrench with 2 fingers in the round grasping area (not at the cover for the perio tip).
  • Page 13: Operation

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 5 Operation 5 Operation Preparation CAUTION Risk of increased development of emphysema. If the pressure is too high during the treatment, there is an increased risk of emphysema developing.
  • Page 14 Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 5 Operation Contraindication ▪ Apical focus ▪ Root caries Treatment procedure: 1. Introduce the perio tip to the floor of the pocket, then pull the perio tip out by 1-2 mm.
  • Page 15: Preparation Methods According To Iso 17664

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 6 Preparation methods according to ISO 17664 | 6.1 Preparations at the site of use 6 Preparation methods according to ISO 17664 Note The reprocessing procedures described in the following apply to the PROPHYflex perio tip, adaptor and wrench.
  • Page 16: Manual Reprocessing

    Malfunction and material damage. ▶ Only disinfect in the washer disinfector. KaVo recommends the following products based on compatibility of the materi- als. The microbiological efficacy must be ensured by the disinfectant manufac- turer and proven by an expert opinion.
  • Page 17: Manual Disinfection - Internal

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 6 Preparation methods according to ISO 17664 | 6.4 Automated reprocessing ▪ FD 322 made by Dürr Consumables required: ▪ Cloths for wiping the medical device. ▶...
  • Page 18: Preparation For Automated Internal And External Cleaning As Well As Internal And External Disinfection

    Please comply with the instructions for use of the washer disinfector. ▶ In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle.
  • Page 19: Care Products And Systems - Servicing

    Prior to attaching the powder container, all powder-conducting parts and air channels must be absolutely dry. Screw together the powder container and handpiece only while the parts are cold. The KaVo medical device has a maximum temperature resistance up to 138 ℃ (280.4 °F). Sterilisation parameters:...
  • Page 20 Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 6 Preparation methods according to ISO 17664 | 6.9 Storage Note Comply with the expiry date of the sterilised items. 20 / 24...
  • Page 21: Tools

    Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 7 Tools 7 Tools Available from dental suppliers. Material summary Mat. no. Adaptor 2.000.1030 O-Ring adaptor 0.200.6019 Wrench 2.000.0901 Nozzle needle 0.410.0911 Refill PROPHYflex perio 1.010.0287 tip (10 units) Service adaptor 3.000.4383...
  • Page 22: Terms And Conditions Of Warranty

    / applications or 12 months from the date of the invoice, sub- ject to the following conditions: In case of justified complaints, KaVo will honour its warranty with a free re- placement or repair. Other claims of any nature whatsoever, in particular with respect to compensation, are excluded.