KaVo Dental GmbH. All other trademarks are property of their respective owners. KaVo Original Factory Repair In the event of a repair, please ship your product to the KaVo Original Factory Repair using www.kavobox.com. KaVo Technical Service If you have any questions or complaints, please contact the KaVo...
Page 5
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 1 User instructions Thermodisinfectable Information on the packaging Material number Serial number Manufacturer Note: Please note accompanying documents Follow the electronic instructions for use HIBC Code CE mark for medical devices Medical device, labelling of medical devices Transportation and storage conditions...
Page 6
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 1 User instructions CAUTION In cases which – if not prevented – can lead to minor or moderate in- jury. NOTICE In cases which – if not prevented – can lead to material damage. 6 / 24...
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 2 Safety | 2.1 Infection hazard 2 Safety Note All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
▶ Both patient and user have to wear protective goggles during the treat- ment. ▶ KaVo recommends the use of dust extraction equipment and mouth protec- tion during the treatment with PROPHYflex. 8 / 24...
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 3 Product description | 3.1 Purpose – Intended use 3 Product description PROPHYflex Perio Kit – 1.009.3731 ① 1 x adaptor, ② 3 x perio tip, ③ 1 x wrench, ④ 1 x nozzle needle In addition, the PROPHYflex Perio Kit (Mat.
Dispose of and recycle the packaging appropriately in accordance with current packaging law, employing waste management / recycling companies. Comply with the comprehensive return system. KaVo has had its packaging licensed for this purpose. Please comply with the regional public waste-disposal system.
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 4 Startup and shut down | 4.1 Inserting the adaptor into the PROPHYflex 4 Startup and shut down WARNING Hazard from contaminated products. Infection hazard for care provider and patient. ▶...
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 4 Startup and shut down | 4.4 Removing the PROPHYflex perio tip Note In order to screw it on, hold the wrench with 2 fingers in the round grasping area (not at the cover for the perio tip).
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 5 Operation 5 Operation Preparation CAUTION Risk of increased development of emphysema. If the pressure is too high during the treatment, there is an increased risk of emphysema developing.
Page 14
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 5 Operation Contraindication ▪ Apical focus ▪ Root caries Treatment procedure: 1. Introduce the perio tip to the floor of the pocket, then pull the perio tip out by 1-2 mm.
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 6 Preparation methods according to ISO 17664 | 6.1 Preparations at the site of use 6 Preparation methods according to ISO 17664 Note The reprocessing procedures described in the following apply to the PROPHYflex perio tip, adaptor and wrench.
Malfunction and material damage. ▶ Only disinfect in the washer disinfector. KaVo recommends the following products based on compatibility of the materi- als. The microbiological efficacy must be ensured by the disinfectant manufac- turer and proven by an expert opinion.
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 6 Preparation methods according to ISO 17664 | 6.4 Automated reprocessing ▪ FD 322 made by Dürr Consumables required: ▪ Cloths for wiping the medical device. ▶...
Please comply with the instructions for use of the washer disinfector. ▶ In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle.
Prior to attaching the powder container, all powder-conducting parts and air channels must be absolutely dry. Screw together the powder container and handpiece only while the parts are cold. The KaVo medical device has a maximum temperature resistance up to 138 ℃ (280.4 °F). Sterilisation parameters:...
Page 20
Instructions for use PROPHYflex Perio Kit – 1.009.3731 Refill PROPHYflex perio tip – 1.010.0287 6 Preparation methods according to ISO 17664 | 6.9 Storage Note Comply with the expiry date of the sterilised items. 20 / 24...
/ applications or 12 months from the date of the invoice, sub- ject to the following conditions: In case of justified complaints, KaVo will honour its warranty with a free re- placement or repair. Other claims of any nature whatsoever, in particular with respect to compensation, are excluded.
Need help?
Do you have a question about the PROPHYflex 1.009.3731 and is the answer not in the manual?
Questions and answers