Installation And Connection; Selecting The Location - Atag KD84178AFC Instructions For Use Manual

Hide thumbs Also See for KD84178AFC:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION AND CONNECTION

Selecting the location

Do not place the appliance near a source of heat, such as a gas cooker, radiator or boiler,
etc., and do not expose it to direct sunlight.
Place the appliance in a dry and well aired room. The permitted ambient temperature range
for the appliance depends on the appliance's climate class, which is shown on the type
plate.
Description
Extended temperate
Temperate
Subtropical
Tropical
Do not place the appliance in a room where the temperature can fall below the lowest
permitted ambient temperature: the appliance may not work properly!
Do not place the appliance in a room where the temperature can fall below 5 °C: the
appliance may become defective!
The appliance is not suitable for outdoor use and may not be exposed to rain.
Place the appliance in a room with a sufficient volume of air. The room must have a
volume of at least 1 m
shown on the type plate on the inside of the appliance.
/
/
/
/
/
Class
Ambient temperature range °C
SN
N
ST
T
of air for every 8 grams of refrigerant. The quantity of refrigerant is
3
+10 to +32
+16 to +32
+16 to +38
+16 to +43
Relative humidity
≤ 75%
EN 11