Installation Options; Floor Protection - United States Stove US5522 Owner’s Instruction And Operation Manual

Table of Contents

Advertisement

INSTALLATION

INSTALLATION OPTIONS

Freestanding Unit - supported by pedestal/legs and
placed on a non-combustible floor surface in compliance
with clearance requirements for a freestanding stove
installation.
Alcove Unit - supported by pedestal/legs and placed
on a non-combustible floor surface in compliance with
clearance requirements for an alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.

FLOOR PROTECTION

This unit must be installed on a non-combustible floor
surface. If a floor pad is used, it should be certified or
equal. The floor pad or non-combustible surface should
be large enough to extend a minimum of 6" (153 mm) in
front, 6" (153 mm) on each side, and 1" (26 mm) behind
the stove. Floor protection must extend under and 2"
(51 mm) to each side of the chimney tee for an interior
vertical installation. A Floor Protector of 1" (26 mm) thick
is recommended for this installation.
A
B
B
C
A
Rear (through wall)
B
Side
C
Front
D
Rear (interior vertical)
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home, and alcove applications in
accordance with the clearances given in this manual.
NOTE: The distance on the side of your pellet stove may
need to be greater than the minimum required clearance
for suitable access to the control panel. For safety
reasons, please adhere to the installation clearances and
restrictions. Any reduction in clearance to combustibles
may only be done by means approved by a regulatory
authority.
D
1"
25 mm
6"
152 mm
6"
152 mm
2"
50 mm
5
F
E
G
J
J
E Backwall to unit
F Sidewall to flue
PARALLEL
Sidewall to top edge
G
of unit
H Backwall to flue
CORNER
J Adjacent wall to unit
ALCOVE
K Alcove depth
© 2022 United States Stove Company
H
F
G
J
J
K
9.5"
241 mm
14"
330 mm
8"
203 mm
3"
76.2mm
8"
203 mm
36"
914 mm

Advertisement