NON-MAINTAINED LUMINARIES
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Ni-Cd)
BATTERY PROTECTION
INDICATIONS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
GENERAL
These devices are used indoors (ta 40 C)
in places where emergency luminaires are
needed. The luminaires GR-470 and GR-
472 are suitable for corridors lighting and
the GR-471 and GR-473 for open area
lighting. Each device must be permanently
connected to mains power supply. In
normal operation the battery is charging. In
case of a mains power supply failure the
device will light the illumination led
automatically in emergency mode. When
the mains power supply is restored the
device turns to normal operation.
INSTALLATION
To install the luminaire follow the
installation instructions οn page 2.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance
or testing must be done by authorized
personel only.
2. The device must be connected to the
mains power supply thru a fuse dependent
by the total amount of the line's
load.
3. It is suggested to check every month the
indication LED for battery charging, and by
placing the test card
Page 1 from 5
GR-470
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
158 x 158 x 60,4mm (without decorative bezel)-195 x 195 x 60,4 (with decorative bezel)
Thank you for your trust in our products.
Olympia Electronics - European manufacturer.
power
(A-1900)
(page 5) an
(for LED MODULE specifications see page 4)
GR-471
220-240V AC / 50-60Hz
2,6W / 2,9VA
3,6V/1 Ah
Deep discharge and overcharge protection
Charge LED, Magnetic Test Contact
1,5 hour
1 white power LED
145lm
5 to 40 C
Up to 95%
ABS/PC, PC
3 years (1 year for the battery)
operation test is initiated, to check the
o
emergency cirquit. The illumination source
should light as long as the card is
In the opposite condition contact the
installer.
4. It is sugested to check every 6 months
the minimum autononous duration by
disconnecting the mains power supply.
Count the time that the luminaire lights and
in case of less time than the minimum
autonomous duration the battery must be
r e p l a c e d . I f t h e m e a s u r e d t i m e i s
considerably less than the minimum
autonomous duration
I n c a s e o f b a t t e r y o r l i g h t s o u r c e
replacement, these must be replaced by
parts of the same type, by the manufacturer
or by a competent person.
5. In case of inactive use for a period
greater than 2 months, disconnect the
b a t t e r y b y p u l l i n g o u t t h e b a t t e r y 's
connector.
6. I s not allowed to discard batteries in
t i
to common trash bins, they must
be discarded only
recycling points. Do not incinerate.
GR-472
24 hours
3 hour
80lm
IP42
o
470gr.
contact the installer.
923473001_09_001
GR-473
present.
in battery

Advertisement

loading

Summary of Contents for olympia electronics GR-470

  • Page 1 The illumination source in places where emergency luminaires are should light as long as the card is present. needed. The luminaires GR-470 and GR- In the opposite condition contact the 472 are suitable for corridors lighting and installer.
  • Page 2: Installation Instructions

    4. Reinstall the diffusor and re-tighten the 4 screws in a diagonally manner with a torque of 0,9 N*m. NOTE!! After finishing the installation you must power the luminaire for at least 24 hours in order to completely charge the batteries. The rated autonomous duration can be achieved after this. GR-470, GR-472 GR-471, GR-473 Open Corridor...
  • Page 3 MOUNTING IN SUSPENDED CEILING plastic mounting luminary’s bracket base Required opening 14,5*14,5cm plastic plugs plastic plugs screws screws 1. Detach the front cover by applying pressure using a flat blade screw driver. Next, unfasten the four retaining screws (figure 1) without removing them and remove the diffusor. 2.
  • Page 4: Surface Mounting

    MOUNTING IN SUSPENDED CEILING SURFACE MOUNTING Other possible Cable entry holes 1. Detach the front cover by applying pressure using a flat blade screw driver. Next, unfasten the four retaining screws without removing them and remove the diffusor. 2. Use a drill with a 3,5mm bit to open the 4 mounting holes (figure 2) located in the plastic base.. 3.
  • Page 5: Labeling Explanation

    LED MODULE CHARACTERISTICS GR-470 GR-471 GR-472 GR-473 Olympia Electronics S.A. Manufacturer Model Number 0205183 Voltage Range 5.6-6.6V DC Nominal Power Connections fixed connection between main pcb and led module Temperature (tc) 55 °C max. across the board Manual TEST with the A-1900 Test card (not included and is available only on request).
  • Page 6: Warranty

    Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

This manual is also suitable for:

Gr-471Gr-472Gr-473