Download Print this page
Analytic Systems IPSi505MW Installation & Operation Manual

Analytic Systems IPSi505MW Installation & Operation Manual

Intelligent puresine inverter

Advertisement

Quick Links

INSTALLATION &
OPERATION MANUAL
IPSi505MW
INTELLIGENT
PURESINE
INVERTER
An ISO9001 Registered Company
Battery Chargers
Inverters
Power Supplies
Voltage Converters
101-8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)
www.analyticsystems.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the IPSi505MW and is the answer not in the manual?

Questions and answers

Summary of Contents for Analytic Systems IPSi505MW

  • Page 1 INSTALLATION & OPERATION MANUAL IPSi505MW INTELLIGENT PURESINE INVERTER An ISO9001 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 101-8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.com...
  • Page 2 Copyright (2005-2022) Analytic Systems Ware (1993) Ltd. Revised - June 13, 2022...
  • Page 3 Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen...
  • Page 4: Table Of Contents

    • Main Parts • Operation • Controls and Indicators • Installation • DC Connections / AC Connections • Off-line UPS Option • InverterWizard (Optional) • Troubleshooting • Specifications • Warranty Copyright Analytic Systems Ware (1993) Ltd. Revised - June 13, 2022...
  • Page 5 1 IPSi505MW Intelligent Pure Sine Inverter • 1 compatible USB cable • 1 Warranty Card • This User Guide (A PDF copy can be downloaded from www.analyticsystems.com) If anything is missing or damaged please contact your dealer or Analytic Systems for a replacement.
  • Page 6: Main Parts

    Main Parts Front Panel LED Indicators Remote Control Connection AC Output Connection: Amphenol USB Communications Port Industrial NEMA 5-15 compatible Power Switch 7-8648-5 connector DC Input Connection: Amphenol (Note: This receptacle is only water- circular MIL-Spec MS3470W14-4P tight with protective cap in place) Connector Back Panel (Not pictured) Chassis Grounding Stud...
  • Page 7: Operation

    Operation This unit is designed for simple and intuitive operation. Before operating, the inverter must be properly installed and connected. See Installation and AC/DC Connections for more information. TO OPERATE THE INVERTER: Move the Power Switch to ON to energize the circuitry. The Invert LED and either the 50 Hz or 60 Hz LED will glow green indicating proper operation and the presence of AC power at the outputs.
  • Page 8: Installation

    Installation MOUNTING Mount the unit in a WELL VENTILATED area. Allow at least one inch (2.54 cm) of clearance all around the unit for adequate cooling. This unit is built to meet the IP66 rating, for protection again high-pressure water spray. Please take this into consideration when choosing a mounting location.
  • Page 9 DC Connections IMPORTANT: BEFORE CONNECTING OR DISCONNECTING ANYTHING TO THE INVERTER, THE POWER SWITCH MUST BE TURNED OFF. DC INPUT CONNECTION This unit is equipped with an Amphenol circular MIL-Spec MS3470W14-4P Connector to serve as a DC Input Connection. Connect the DC power source here using wiring suitable for the input amps.
  • Page 10: Off-Line Ups Option

    Off-line UPS Option The Off-line UPS (Uninterruptible Power Source) option allows the inverter to function as a backup power source in the event of external AC power failure. Units with the offline UPS feature are constructed with an AC Input connection and internal off-line AC Bypass circuit. NORMAL OPERATION •...
  • Page 11: Inverterwizard (Optional)

    InverterWizard (Optional) InverterWizard is optional software that can be used to adjust the inverter’s operating settings. InverterWizard is free-to-download from www.analyticsystems.com or available by emailing sales@analyticsystems.com Using InverterWizard, you can: • Set the inverter’s output frequency to either 50.00 or 60.00 Hz. •...
  • Page 12: Troubleshooting

    Troubleshooting This unit features eight LED indicators and an alarm buzzer to help diagnose any malfunctions during operation. In the event of malfunction, the alarm buzzer will sound prior to the inverter shutting down. You should immediately check which LEDs are glowing to determine the cause of the malfunction.
  • Page 13: Specifications

    Specifications Input Nominal Voltage 24, 28, 32, or 36 VDC 48 or 72 (Rail) VDC Actual Voltage 20-45 VDC 40-90 BDC Input Amps (Max.) 28 A 14 A Under Voltage Input Alarm 19-36 VDC 39-70 VDC Shutdown Range (Default setting: 21 VDC) (Default setting: 42 VDC) Under Voltage Input Alarm 20-36 VDC...
  • Page 14: Warranty

    2 Years parts and labour Emissions Designed to meet MIL461F * Specifications subjects to change without notice. Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. 101-8128 River Way p. 604.946.9981 f. 604.946.9983 Delta, B.C. V4G 1K5 Canada tf. 800.668.3884 US/Canada www.analyticsystems.com...
  • Page 15 2 Years from date of manufacture for non-standard or OEM products 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or...
  • Page 16 DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 Support@analyticsystems.com www.analyticsystems.com Battery Chargers • Inverters • Power Supplies • Voltage Converters 101-8128 River Way Delta, BC V4G 1K5 | Canada Register Products Online | www.analyticsystems.com/support/warranty-registration...