Page 1
INSTALLATION & OPERATION MANUAL IPSi365 INTELLIGENT PURE-SINE INVERTER An ISO9001 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.AnalyticSystems.com...
Page 2
Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen...
• Main Parts • Operation • Controls and Indicators • Installation • Input Connections / Output Connections • Offline UPS Option • InverterWizard • Troubleshooting • Specifications • Warranty Copyright Analytic Systems Ware (1993) Ltd. Revised - August 19, 2019...
Page 4
1 Warranty Card • This User Guide (A PDF copy can be downloaded from www.analyticsystems.com) • Optional InverterWizard software can be downloaded from www.analyticsystems.com If anything is missing or damaged please contact your dealer or Analytic Systems for a replacement.
Main Parts Front Panel Remote Control Connection Power Switch DC Input Connection: Color- USB Communications Port coded Phoenix VFDK Terminal AC Output Connection 1: NEMA Blocks (Red: DC Positive, Black 5-15 Outlet DC Negative) AC Output Connection 2: Color- coded Phoenix VFDK Terminal Blocks (Gray: AC Neutral, Green: AC Ground, Black: AC Hot) Top Chassis...
Operation This unit is designed for simple operation. Before operating, the inverter must be properly installed and connected. See Installation and AC/DC Connections for more information. TO OPERATE THE INVERTER: Move the Power Switch to ON to energize the circuitry. The Invert LED and either the 50 Hz or 60 Hz LED will glow green indicating proper operation and the presence of AC power at the outputs.
Page 7
Operational Indicators There are eight LED indicators on the inverter’s top chassis which display the unit’s operating condition. The table below details their meaning: LEDs Meaning • Blinks red when the input voltage nears the minimum limit for operation. VOLTAGE •...
Installation MOUNTING Mount the unit in a DRY and WELL VENTILATED area. Allow at least one inch (2.54 cm) of clearance all around the unit for adequate cooling. CAUTION: DO NOT MOUNT THE UNIT ANYWHERE EXPLOSIVE GASES CAN ACCUMULATE. A slight arc may occur when the power leads are connected, and in the unlikely event of a failure, sparks may be generated inside the unit.
Page 9
DC Input Connections DC INPUT POWER CONNECTION This unit is equipped with a pair of color-coded Phoenix VDFK6 terminal block connectors to serve as a DC Input Connection. Connect the DC input power here using AWG8/10mm wire. The wires should be stripped 0.4 inches/9mm and tightened securely to 16 inch-pounds/1.8 Newton Meters.
Off-line UPS (Optional) The Off-line UPS (Uninterruptible Power Source) option allows the inverter to function as a backup power source in the event of external AC power failure. NORMAL OPERATION • The AC power source supplies AC power to both the battery charger and the load (Running through the AC Power Source Inverter...
Page 11
InverterWizard (Optional) InverterWizard is optional software that can be used to adjust the inverter’s operating settings. InverterWizard is free-to-download from www.analyticsystems.com or available by emailing sales@analyticsystems.com Using InverterWizard, you can: • Set the inverter’s output frequency to either 50.00 or 60.00 Hz. •...
Troubleshooting This unit features eight LED indicators and an alarm buzzer to help diagnose any malfunctions. In the event of malfunction, the inverter will sound the buzzer to alert you prior to shutting down its output. You should immediately check which LEDs are glowing to determine the cause of the malfunction.
General Length 13.0 in / 32.8 cm Width 8.0 in / 20.3 cm (Including mounting flanges) Height 3.3 in / 8.3 cm Clearance 1.0 in / 2.5 cm Weight 16.0 lb / 7.3 kg Material Marine-grade aluminum Finish Black anodized Fastenings 18-8 Stainless steel AC: Phoenix VDFK4 32 Amp / 500V terminal block (Off-line UPS Option mandatory)
Page 15
2 Years from date of manufacture for non-standard or OEM products 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or...
Page 16
DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 Support@analyticsystems.com www.AnalyticSystems.com Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way Delta, BC V4G 1K5 | Canada Register Products Online | www.analyticsystems.com/support/warranty-registration...