Summary of Contents for Analytic Systems IPSi305M-20-220ZAS
Page 1
INSTALLATION & OPERATION MANUAL IPSi305M-20-220ZAS INTELLIGENT PURESINE INVERTER An ISO9001 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters Tecknowledgey Defense, 8 John Walsh Blvd, Peekskill, NY 10566 USA T. 914.739.4499 F. 914.739.5599 defense.tecknowledgey.com...
Page 2
Copyright (2005-2020) Analytic Systems Ware (1993) Ltd. Revised - Feb 20, 2020...
Page 3
Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen...
• Introduction / Box Contents • Main Parts • Operation • Controls and Indicators • Installation • Input Connections / Output Connections • Troubleshooting • InverterWizard • Specifications • Warranty Copyright Analytic Systems Ware (1993) Ltd. Revised - February 20, 2020...
Page 5
1 Warranty Card • This User Guide (A PDF copy can be downloaded from www.analyticsystems.com) • Optional InverterWizard software can be downloaded from www.analyticsystems.com If anything is missing or damaged please contact your dealer or Analytic Systems for a replacement.
Main Parts Front Panel USB Communications Port Power Switch AC Output Connection: Amphenol DC Input Connection: Amphenol circu- circular GTS02R10SL-3S connector c/w lar MIL-Spec MIL-Spec GTS02R-20-23P protective cover connector c/w protective cover Remote Control Connection...
Operation This unit is designed for simple operation. Before operating, the inverter must be properly installed and connected. See Installation and AC/DC Connections for more information. TO OPERATE THE INVERTER: Move the Power Switch to ON to energize the circuitry. The Invert LED and either the 50 Hz or 60 Hz LED will glow green indicating proper operation and the presence of AC power at the outputs.
Page 8
Operational Indicator There are eight indicator LEDs on the inverter’s top panel which display it’s operating condition. The table below details their meanings: LEDs Meaning • Blinks red when the input voltage nears the minimum limit for proper operation. VOLTAGE •...
Installation MOUNTING Mount the unit in a DRY and WELL VENTILATED area. Allow at least one inch (2.54 cm) of clearance all around the unit for adequate cooling. CAUTION: DO NOT MOUNT THE UNIT ANYWHERE EXPLOSIVE GASES CAN ACCUMULATE. A slight arc may occur when the power leads are connected, and in the unlikely *Shown with optional carrying handle event of a failure, sparks may be generated inside the unit.
Page 10
DC Input Connections DC INPUT CONNECTION This unit is equipped with an Amphenol circular MIL-Spec GTS02R-20-23P connector c/w protective cover to serve as a DC Input Connection. Wire color Polarity Pin A DC Positive Pin B DC Negative CAUTION: DO NOT REVERSE CONNECT THE DC INPUT This will damage the Inverter and will not be covered under warranty.
Troubleshooting This unit features eight LED indicators and an alarm buzzer to help diagnose any malfunctions. In the event of malfunction, the inverter will sound the buzzer to alert you prior to shutting down its output. You should immediately check which LEDs are glowing to determine the cause of the malfunction.
Page 12
InverterWizard (Optional) InverterWizard is optional software that can be used to adjust the inverter’s operating settings. InverterWizard is free-to-download from www.analyticsystems.com or available by emailing sales@analyticsystems.com Using InverterWizard, you can: • Set the inverter’s output frequency to either 50.00 or 60.00 Hz. •...
Specifications Input Nominal Voltage 24, 28, 32 or 36 VDC Actual Voltage 20 - 45 VDC Input Amps (Max.) 24 A Input Fuse (Internal) 1 x ATC30 Output -220 Actual Voltage 220 +/- 4 VAC Continuous Output Amps 1.5 A Peak Output Amps 1.8 A Output Frequency...
Page 14
This page has been left intentionally left blank...
Page 15
2 Years from date of manufacture for non-standard or OEM products 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or...
Page 16
DESIGNED AND MANUFACTURED BY 914-739-4499 914-739-5599 Infor@tecknowledgey.com defense.tecknowledgey.com Battery Chargers • Inverters • Power Supplies • Voltage Converters Tecknowledgey Defense 8 John Walsh Blvd Peekskill, NY 10566 USA Register Products Online | www.analyticsystems.com/support/warranty-registration...
Need help?
Do you have a question about the IPSi305M-20-220ZAS and is the answer not in the manual?