Table of Contents

Advertisement

3 .10 .1 Ascent rate

The LUNA 2.0 AI employs a variable ideal ascent rate. Its value ranges from 3 to 10m/min (10 to 33ft/min) and the
actual breakdown by depth range is listed in the table below.
m
0
2.5
6
12
18
23
31
35
39
44
50
120
If you ascend too quickly, the resulting pressure reduction could lead to microbubble formation. If you ascend too
slowly, the continued exposure to high ambient pressure means you will continue loading some or all of your tissues
with nitrogen.
If the ascent rate is greater than 110% of the ideal value, the SLOW DOWN alarm is shown.
The ascent speed bar in the above screen represents the following:
1 bar -> speed = 20-40%
2 bars -> speed = 40-60%
3 bars -> speed = 60-80%%
4 bars -> speed = 80-100%
5 bars -> speed = 100-110%
6 bars -> speed > 110%
LUNA 2.0 AI USER MANUAL
DEPTH
ft
0
8
20
40
60
75
101
115
128
144
164
394
ASC SPEED
m/min
3
5.5
7
7.7
8.2
8.6
8.9
9.1
9.4
9.6
9.8
10
ft/min
10
18
23
25
27
28
29
30
31
32
33
33
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna 2.0