Baby Lock BLTA Altair Technical Training Manual page 43

Hide thumbs Also See for BLTA Altair:
Table of Contents

Advertisement

Left Base Line Needle Drop Position
Standard: Left base line needle drop is in "V" shape
1. Go to the test mode #4 and move the
needle to the left by pressing the button (#1).
2. Turn the pulley until the needle point
comes to the needle plate surface.
3. Loosen the black screw (#2) and turn
the eccentric screw (#3) to adjust the
needle drop position.
4. Tighten the screw (#2).
shadow area of needle plate.
#1
41
#2
#3

Advertisement

Table of Contents
loading

Table of Contents