Savant Power Storage 20 Installation Manual page 19

Hide thumbs Also See for Power Storage 20:
Table of Contents

Advertisement

3.7.2 AC Coupled Solar Wiring
The Savant Power Storage 20 enables easy integration of a grid tied solar installation to enable continued solar production in a grid down scenario. It
is recommended to use a UL 1741SA compliant inverter when AC coupling into the Savant Power Storage 20.
CAUTION! Do not interconnect a generator to a system that is installed with AC Coupled solar attached as it can lead to damage to the
generator and inverter!
1.
Land the output of the AC coupled solar inverter into the GEN input of the inverter or into the backed-up load center.
NOTE: The PS-INV-12.5KW-60A-XX model will only support AC coupling into the backed-up load center whereas the PS-INV-12.5KW-100A-XX
can support either location
NOTE: Paralleled systems should only have AC coupling into the GEN input of the inverter.
2.
Use the Savant Power Storage app to program the parameters of the AC coupled system.
Savant Power Storage 20 Installation Guide
009-2401-00 | 090623
- 19 -
Copyright 2023 Savant Systems, Inc