Introduction; Transporting The Unit; Receipt Of Goods; Checking The Equipmentl - Carrier AQUASNAP 30WI Installation, Operation And Maintenance Instructions

Heat pumps and liquid coolers with water cooled condenser
Hide thumbs Also See for AQUASNAP 30WI:
Table of Contents

Advertisement

1 - INTRODUCTION

AQUASNAP 30WI series water chiller units are designed to meet the air conditioning and heating requirements of residential and 
office buildings as well as the requirements of industrial processes. AQUASNAP 30WI series units are liquid chillers with water-cooled 
condensers which guarantee safe and reliable operation in the operating range for which they have been designed.
All the units are factory tested and checked. They are supplied with a full refrigerant charge.
These units meet standard EN 60-204 and standard EN378-2 as well as the following European directives:
- Machinery 2006/42 EC
- EMC 2014/30/EU
- LVD 2014/35/EU
- RoHS 2011/65/EC:
- PED 2014/68/EU, see table below
AQUASNAP 30WI
Categories
Pressure and temperature:
Test pressure (TP): because of the harmful effects it has on the unit, this test is carried out on a model representative of all 3 x PS 
assemblies in compliance with § 5.3.2.2 a and 6.3.3 iii of standard 378-2.
Shipment temperature:
Min. -30°C - Max. +50°C.
Storage temperature:
Min. -30°C - Max. +50°C.
Operating temperature:
Refer to section 9, "Operating limits", in these instructions.
Technicians who install, start up, operate and service the unit must possess the necessary training and certifications, understand the 
instructions given in this manual and be familiar with the specific technical characteristics of the installation site.
If they are to work on the unit's refrigeration circuit, such training and certification must meet the requirements of Regulation (EC) 
842/2006.

2 - TRANSPORTING THE UNIT

During shipment, the unit must be securely strapped in place to prevent it moving and to protect it from damage.
If the unit is shipped in a container, the container must be easy to load and unload.
Do not lift the unit using these accessories.

3 - RECEIPT OF GOODS

3.1 - Checking the equipmentl

Check the unit for any damage or missing components upon delivery.
Note any damaged or missing parts on the delivery slip.
IMPORTANT:
You must notify the carrier of any damage and/or missing parts by registered letter within three days of the delivery date.
Furthermore, ensure the unit is not stored in an outdoor location exposed to the elements.

3.2 - Identifying the equipment

Name plate:
Each unit has a manufacturer's name plate (A) bearing the unit's identification number (serial number) 
and description.
4
700V to 1000V
1100V to 1200V
II
1400V to 1800V
III
II
2100V to 2400V
III
AQUASNAP 30WI
A