Each Energy PHS3K-M1A User Manual page 22

Table of Contents

Advertisement

ports on inverter to monitor electricity parameter such as current, voltage,
power, etc. and to realize export power management.
The suggested parameter:
Max input current for meter: 120A
Max measuring current for CT: 100A
Detail specifications of meter and CT can be found on Each Energy
Website and a customer can purchase a suitable meter and CT for
inverters on the website.
NOTE
No need to change any parameter of the meter as it has been preset in the
factory!
Meter and CT connection:
For more information about meter and CT connection, please refer to
corresponding manuals on Each Energy website.
The following is schematic diagrams for reference.
Single Phase Meter Installation Electrical Diagrams
CT Installation Electrical Diagrams