Summary of Contents for Each Energy EES6KPro-M1

  • Page 1 Each Energy Technology (Suzhou) Co., Ltd. Address: No.8 Building, No. 38 of Beiguandu Road, Yuexi Street, Wuzhong District, Suzhou, Jiangsu Province, China Tel: +8651266581088 Email: service@eachenergy.com Web: www.eachenergy.com Each Energy Technology (Suzhou) Co., Ltd. www.eachenergy.com Copyright © Each Energy Technology (Suzhou) Co., Ltd.
  • Page 2: Table Of Contents

    Contents Copyright © Each Energy Technology (Suzhou) Co., Ltd. 1. About the Manual ......................3 Without written permission, any information of this document (partly or 2. Product Overview .......................4 entirely) cannot be extracted, copied or transmitted in any form or by any 3.
  • Page 3: About The Manual

    Valid Region This manual applies to the operation of Each Energy inverters in Australia, New Zealand, the UK, EU, South America, North America, and Southeast Asia. Name...
  • Page 4 2.2 Front Panel 2.3 Scope of Delivery Operation Panel: Description Quantity Name Communications Power Alarm Down Enter Inverter Light Light Light Wall Bracket Expansion Screws LED Light: Fastening Screws DC Connectors 4 (pairs) Light Status Explanation AC Connectors POWER The inverter is generating power WiFi/GPRS Stick The inverter is not generating power Documents...
  • Page 5: Mounting

    requirements of local power authorities. 3. Safety  Wear protective equipment for all work on the machines: helmet, insulated footwear, gloves, etc.  Ensure that unauthorized persons and children have no access to the 3.1 Safety Symbols machines.  Do not open the housing of the machines at any time. Unauthorized Symbol Explanation opening will void guarantee and warranty and may damage the...
  • Page 6: Inverter Mounting

    The following points should be considered when selecting an installation location.  The wall bearing inverters shall be able to hold the weight of at least 4 times of the weight of the inverters.  The location shall be convenient for electrical connection, operation and maintenance.
  • Page 7: Electrical Connection

    5. Electrical Connection 5.1 DC Side Connection of Inverters 3) Thread the cable through the Cable Gland, insert it into the insulator, and gently pull backward the cable to ensure firm connection. Then screw up the Cable Gland to the Insulator. DANGER ELECTRICAL SHOCK Lethal high voltage will be generated by PV arrays under sunlight, so please disconnect DC and AC breakers and ensure no possibility of...
  • Page 8 When connecting an inverter to the utility grid, please use 4 – 6 mm² outdoor cable. For Each energy 3 KW to 4 KW inverters, it is recommended to use 4 mm² cable, and for 5 KW to 6 KW inverters, use 6 mm² cable.
  • Page 9: Over Current Protection Device

    LCD will display ‘ISO Out Range’ or ‘PEN No Connect’. In that case, please refers to Chapter 7 for troubleshooting or contact Each Energy for help.
  • Page 10: Electrical Connection Overview

    1) Plug the stick to the Wifi port on the inverter Detail specifications of meter and CT can be found on Each Energy Website 2) Rotate the front operative part of the stick clockwise till the secure and a customer can purchase a suitable meter and CT for inverters on the connection of the stick website.
  • Page 11: Operation

    When a DRED is connected to an inverter, the inverter will receive and 5.9 Residual Current Device (RCD) response to the outside signal directly. And the DRM working mode will be shown in the BASIC INFO in the LCD menu. An internal residual current device is integrated in the inverter to protect against any potential residual current.
  • Page 12: Lcd Operation

    6.2.2 Basic Info. CAUTION WAIT The table below explains the meaning of information displayed in the Beware of the risk of electrical shock! Wait at least 5 minutes before sub-menu of Basic Info. touching the machine although the DC switch has been turn off! 6.2 LCD Operation Displays Duration...
  • Page 13: Basic Setup

    AC voltage: the voltage of the utility To set up RS485 address SET RS485 ADDR AC VOL: 230.6V grid 10 S AC CUR: 38.8A AC current: the current of the utility To set up language SET LANGUAGE grid Frequency: the frequency of the utility GRID FREQ:50.2Hz 10 S grid...
  • Page 14 10 S This menu indicates: Heatsink Temp NEXT = ENT EXIT = ESC The temperature of heat sink of 65.5 Password: 0000 ℃ inverters Steps to view the menu of the Detail Info.: 10 S This menu indicates: Inner Temp Inverter inner temperature 45.0 ℃...
  • Page 15 10 S This menu indicates the power Export Power 6.2.4.5 Rated Power exported to grid 4800W The rated power of the inverter is displayed here. Rated Power The operation info of inverter and part of protection info. can be view after password has been input and all the info.
  • Page 16: Technical Set - Maintenance Personnel Only

    To set up the max generation Pmax Limit power To set up the AC instant voltage AC Inst Limit limit 6.2.5 Technical Set – Maintenance Personnel Only To set up the power control This section is for maintenance personnel only, enter password to access the Power Control sub-menu as guided by Chapter 6.2.4.
  • Page 17 confirm the safety standard, and press ESC to return to the previous menu. To set up export power limit Export Limit NOTE: This operation is for maintenance personnel only. Password Press UP/DOWN to scroll the menu, press ENT to access the sub-menu, and is required to access this part! press ESC to return to the previous menu.
  • Page 18 LCD Display Explanation Procedures to set up the gradient of power rate limit: To set up reactive power Step1: Go to ‘All Set Enable’ in the menu of ‘TECHNICAL SET’ and turn the status to ‘ON’. +60% Step2: Go to ‘Standard Func’ and then get inside. To set up power factor Step3: Go to set up the ‘...
  • Page 19 MPPT mode To enable the shadow To enable the DC component inspection DCI Prot Shadow MPPT: To enable the GFCI protection GFCI Prot 6.2.5.8.1 Island Protection The active anti-islanding protection of the inverters is achieved by shifting the frequency of the inverter away from nominal conditions in the absence of a To enable the ISO protection ISO Prot reference frequency (frequency shift).
  • Page 20 Inverter reactive supplying absorbing power level (Q)% of S rated Voltage 207 V 220 V 235 V 244 V Zealand Inverter reactive supplying absorbing power level (Q)% of S rated Procedures to enable or disable the Volt-var Response Mode: Step1: go to ‘All Set Enable’ in the menu of ‘TECHNICAL SET’ and turn the status to ‘ON’.
  • Page 21 status to ‘ON’ or ‘OFF’. NOTE: This operation is for maintenance personnel only. Password is required to access this part! 6.2.5.8.4 Fixed Power Factor Mode or the Reactive Power Mode PF CURVE Q CURVE Those modes are disabled by default. The fixed power factor mode or the reactive power mode may be enabled in some situations by the electrical Region Default Value...
  • Page 22: Maintenance And Troubleshooting

    6.2.5.9 Password Set-up Press UP/DOWN to scroll the menu, press ENT to perform the selection, and The password for ‘Detail Info’ and ‘Technical Set’ can be reset here. press ESC to return to the previous menu. 6.2.5.14 Export Limit Password: 1100 ->Soft Limit Mode:...
  • Page 23 PV current DC Over 1. Restart the inverter exceeds the Current 2. Decrease solar panels quantity hardware 7.2 Disposing of Inverters Hard in parallel if it occurs repeatedly protection limit 1. Check if the input voltage If the inverters need to be disposed of, please do that according to the local Transient bus exceeds the inverter's upper limit regulations for electrical equipment waste, and choose the right site for the...
  • Page 24 installer Fault in current GFCI Device Restart the inverter or contact leakage testing Fault the installer Check if the ambient temperature device Temperatu Low Temperature is below normal working re Inside Inside Inverters temperature of inverters and ACHCT Inverters increase ambient temperature Fault in HCT device Restart inverter or contact the Device...
  • Page 25: Specification

    1. Check the ventilation of Fault in Temp is Temperature is Restart the inverter or contact installation environment Relay Fault grid-connection Too High too high the installer 2. Avoid direct sunlight relay Check if the ambient temperature Communication Temp is Temperature is is below normal working MS Comm...

This manual is also suitable for:

Ees7k-m1Ees8k-m1Ees9k-m1Ees10k-m1