2. Make sure that the room temperature is within operating specifications.
3. Upgrade all system and chassis (if applicable) firmware to the latest level.
4. If problem persists, collect Service Data log.
5. Contact Lenovo Support.
• FQXSPPU0011N: An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has
asserted.
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0816
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. Reboot system.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPPU2001I: An Over-Temperature Condition has been removed on [ProcessorElementName].
This message is for the use case when an implementation has detected a Over-Temperature Condition
has been Removed for Processor.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0037
User Action:
Information only; no action is required
• FQXSPPU2002I: The Processor [ProcessorElementName] is no longer operating in a Degraded
State.
This message is for the use case when an implementation has detected a Processor is no longer running
in the Degraded state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0039
User Action:
Information only; no action is required