Lenovo ThinkSystem SR950 V3 Manual page 155

Messages and codes reference
Hide thumbs Also See for ThinkSystem SR950 V3:
Table of Contents

Advertisement

1. This event should be followed by a recent FQXSFIO0005M / FQXSFIO0006M event denoting some
UPI links failure which caused UPI topology downgrade.
2. Solve the event FQXSFIO0005M / FQXSFIO0006M at first, then this event should be solved
automatically.
3. If no recent or after fixing FQXSFIO0005M / FQXSFIO0006M event, this event still persists, collect
Service Data logs and contact Lenovo Support.
• FQXSFIO0006M: An inter-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
Parameters:
[arg1]: Socket number, 1-based [arg2]: Port Number [arg3]: Socket number, 1-based [arg4]: Port Number
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFIO0007M: An error has been detected by the IIO on Bus [arg1]. The value of Global Fatal
Error Status register is [arg2]. The value of Global Non-Fatal Error Status register is [arg3]. Please
check error logs for additional downstream device error data.
Severity: Error
Parameters:
[arg1]: Bus [arg2]: Global Fatal Error Status register value [arg3]: Global Non-Fatal Error Status register
value
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFIO0008M: An intra-board UPI dynamic link width reduction has been detected on the link
between processor [arg1] port [arg2] and processor [arg3] port [arg4].
Severity: Warning
Parameters:
[arg1]: Socket number, 1-based [arg2]: Port Number [arg3]: Socket number, 1-based [arg4]: Port Number
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
.