Lenovo ThinkSystem SR950 V3 Manual page 116

Messages and codes reference
Hide thumbs Also See for ThinkSystem SR950 V3:
Table of Contents

Advertisement

1. Make sure that the correct login ID and password are being used.
2. Have the system administrator reset the login ID or password.
• FQXSPSE4004I: Remote access attempt failed. Invalid userid or password received. Userid is
[arg1] from WEB browser at IP address [arg2].
This message is for the use case where a remote user has failed to establish a remote control session
from a Web browser session.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Remote Login
SNMP Trap ID: 30
CIM Prefix: IMM CIM ID: 0018
User Action:
Make sure that the correct login ID and password are being used.
• FQXSPSE4005I: Remote access attempt failed. Invalid userid or password received. Userid is
[arg1] from TELNET client at IP address [arg2].
This message is for the use case where a user has failed to log in to a Management Controller from a
telnet session.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Remote Login
SNMP Trap ID: 30
CIM Prefix: IMM CIM ID: 0019
User Action:
Make sure that the correct login ID and password are being used.
• FQXSPSE4006I: XCC detected an invalid SSL certificate in the Management Controller [arg1] .
This message is for the use case where a Management Controller has detected invalid SSL data in the
configuration data and is clearing the configuration data region and disabling the SSL.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0034
User Action:
Complete the following steps until the problem is solved:
1. Make sure that the certificate that you are importing is correct and properly generated / certificate
CSR is correct
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPSE4007I: Security: Userid: [arg1] using [arg2] had [arg3] login failures from an SSH client at
IP address [arg4].
112
ThinkSystem SR950 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dc47dc57dc6

Table of Contents