Stairville Tri Flat PAR Profile 5x3W RGB 25 User Manual page 30

Led par
Table of Contents

Advertisement

Operating
DMX-Modus
Operating mode 'Slave'
Tri Flat PAR Profile 5x3W RGB 25°, 45°
30
LED PAR
This setting is only relevant when the unit is DMX-controlled.
Press [Mode] repeatedly until the display shows 'd.xxx' .
Now you can set the number of the first DMX channel to be used by the device (DMX address).
Use [Up] and [Down] to select a value between 1 and 512 (display shows 'd.001' ... 'd.512' ).
Make sure that this number matches the configuration of your DMX controller. The following
table shows the highest possible DMX address for the various DMX modes.
Mode
3-channel
5-channel
7-channel
Press [Setup]. Now use [Up] and [Down] to select one of the following DMX operating modes:
'3-ch' (three channels)
n
'5-ch' (five channels)
n
'7-ch' (seven channels)
n
This setting is only relevant when the unit is working as Slave in a Master / Slave combination
and is not DMX-controlled.
Press [Mode] repeatedly until the display shows 'SLAv' .
Highest possible DMX address
510
508
506