Maintenance; Troubleshooting (Check Point) - Toshiba RAS-35S4KVDG-ND Owner's Manual

Hide thumbs Also See for RAS-35S4KVDG-ND:
Table of Contents

Advertisement

Available languages

Available languages

15
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of
2 air conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the back side of Remote Control "00" will be
shown on the display. (Picture 1)
4. Press
during pushing
"00" will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized. (Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
16
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set temperature,
the fan speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of
plastic.
Note: Item 2 to 6 for Heating model.
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Heating
–30°C ~ 24°C
Cooling
–15°C ~ 46°C
Dry
–15°C ~ 46°C

MAINTENANCE

17
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Controller
● Clean the indoor unit and the remote controller with a wet cloth when
needed.
● No benzine, thinner, polishing powder or chemically-treated duster.
Air filters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air filters.
3. Vacuum or wash and then dry them.
4. Reinstall the air filters and close the air inlet grille.
18

TROUBLESHOOTING (CHECK POINT)

The unit does not operate.
● The power main switch is
turned off.
● The circuit breaker is activated
to cut off the power supply.
● Stoppage of electric current.
● ON timer is set.
. "B" will show on the display and
2
Room Temperature
Less than 28°C
21°C ~ 32°C
17°C ~ 32°C
Cooling or Heating is abnormally low.
● The fi lters are blocked with dust.
● The temperature has been set
improperly.
● The windows or doors are opened.
● The air inlet or outlet of the outdoor unit
is blocked.
● The fan speed is too low.
● The operation mode is FAN or DRY.
● POWER SELECTION function is set
75% or 50% (This function is depend
on remote controller).
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-25s4kvdg-ndRas-35s4avpg-ndRas-25s4avpg-nd

Table of Contents