NE-9970, NE-9970C
NE-9870, NE-9870C
CAUTION
WARNING
WARNING
WARNING
these switches.
{B) When replacing the fuse, confirm that it has the appropriate rating for
these models.
(C) When replacing faulty switches, be sure mounting tabs are not bent,
broken or otherwise, deficient in their ability to hold the switches.
INSULATED
- < @
SCREWDRIVER
H.V. CAPACI TOR
Touch chassis side first then short to the high voltage capacitor ter-
minal.
Fig. 19
6. Confirm after repair
(A) After repair or replacement of parts, make sure that the screws of the
oven, etc. are neither loose nor missing.
Microwaves might leak if screws are not properly tightened.
(B) Make sure that all electrical connections are tight before inserting the
plug into the wall outlet.
(C) Check for microwave energy leakage, (Refer to procedure for
measuring microwave energy leakage on page 30).