8. External input and output

With using external input and output functions, this product can be operated inter-connectedly with
an external device.
Connector
CN14
CN16

8-1. External input

With using external input function, some functions on this product can be controlled from an external
device.
• "Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit.
• A twisted pair cable should be used. Maximum length of cable is 150 m.
• Use an external input and output cable with appropriate external dimension, depending on the
number of cables to be installed.
• The wire connection should be separate from the power cable line.
¢ Control input (Operation/Stop)
The air conditioner can be remotely operated by means of the following on-site work.
Unit operation is started at the following contents by adding the contact input of a commercially avail-
able on/off switch to a connector on the external control PCB and turning it on.
Unit operation
Operation mode
Set temperature
Airflow mode
Air direction (swing)
8-1. External input
Input
Control input
Operation status output
Initial setting after power is on
Auto changeover
24 °C
AUTO
Standard air direction (swing OFF)
Output
Starting mode other than initial setting
Mode at previous operation
Temperature at previous operation
Mode at previous operation
Air direction at previous operation
- 15 -
Remarks
See external input/output
settings for details.