Function Test Power Pack - Husqvarna PP492HF Workshop Manual

Table of Contents

Advertisement

1
3
SERVICE AND MAINTENANCE
SERVICE AND MAINTENANCE
2
Check the Pivoting Arm Play
1� Make a status check by attaching
an indicator clock�
2� Gently move arm back and forth
with two fingers, do not press
hard�
3� Measure the play� It should be less
than ± 1,5 mm at the blade flange
hub�
Large slack might indicate a
worn/damaged gearwheel or a
problem with the gearbox�

Function Test Power Pack

1� Check the emergency stop
function�
2� Check the remote control stop
button function�
3� Check the power indicator
function�
4� Check the single phase output
230 V function (5 pin machines
only)�
5� Check the ground-fault circuit
breaker function�
7
7
21
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws442hfWs482hfPp440hfPp480hfPp490hfWs440hf

Table of Contents