6.3.4

Install Further Cabinet Rows

Step 1)
Install the Cabinet hanger pins (see 6.3.1).
Step 2)
Use the grip handles on the cabinet (Figure 49 in chapter 6.3.2, A) to bring it into
position at left corner on the first cabinet row.
Step 3)
Align together the Cabinet hanger pins with the Mounting bar sockets (Figure 49, B)
and the Corner alignment pins on the cabinet below (Figure 49, C).
Lower the cabinet onto the Network-PS socket (Figure 49, D), gently pressing it until it
sits firmly.
Notice
Place the cabinet carefully and straight on top of the Network-PS socket. Otherwise, the data
connection may be pushed out and not function properly.
Step 4)
Install further cabinets until a row is complete.
Step 5)
Connect each cabinet to its adjacent
cabinets with the Cabinet interlocks.
a)
Push in the lock bolt.
b)
Turn the lock bolt 90° to lock.
c)
Fix the black nut to secure the lock
finger tight.
Notice
Do not tighten the Cabinet interlocks too much.
Otherwise the cabinets cannot be aligned later on.
Step 6)
For the top row, use type B cabinets only.
Proceed as described above.
6.3.5

Align Cabinets

After all rows of cabinets are installed, the cabinets have to be aligned with the Adjustment
plates.
Step 1)
For each cabinet junction, attach one
Adjustment plate (A) with four screws, one on
each cabinet.
Step 2)
Attach Adjustment plates also on the sides of
the LED Wall (B) and at the bottom over the
Power bar (C).
Step 3)
After each cabinet junction has a Adjustment
plate, tighten all Cabinet interlocks hand tight.
By tightening the Cabinet interlocks properly,
the cabinets keep their aligned position.
Step 4)
Remove all Adjustment plates.
b
a

Figure 55: Locking Two Modules

B

Figure 56: Adjustment plates

c
A
C