  • Page 1 User’s Manual for JSmart700 Series Touchscreen Products JSmart700 Series Operating Instructions MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A.
  • Page 2 “as is” without warranty of any kind. Third-party brands and names are the property of their respective owners. www.exorint.com Software available in these products is based on OpenSource. Visit oss.exorint.net for more details. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 3: Table Of Contents

    5.1 Ethernet Port 6 Power Supply, Grounding and Shielding 7 Battery 8 Special Instruction for Use 9 Getting Started 10 System Settings 11 Unpacking and Packing Instructions MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 4: Introduction

    The operational guidelines described below is information which relates to the device, installation, transpor- tation, storage, assembly, use and maintenance. This Operating Instruction describes the main features of the Exor operator panels. The Manual refers to the following models: JSmart707 Field-ready HMI 7”...
  • Page 5: Safety Guide

    ATTENTION: indicates a failure to observe safety rules and that deficiency may cause damage. ATTENTION CAUTION: indicates a failure to observe safety rules and that deficiency may cause defects to the equipment or inconsistencies.  CAUTION MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 6: Product Overview

    JMobile runtime with OPC UA Server and Client • Optional CODESYS V3 PLC for integrated HMI and control applications • Built-in sensors (temperature and acceleration) MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 7: Standards And Approvals

    The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive 2011/65/EU In compliance with the above regulations the products are CE marked. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 8 1920 serial number AA00012P9000000561AA manufacturer address Exor International S.p.A. Via Monte Fiorino 9 IT-37057 San Giovanni Lupatoto (VR) Ordering code key Example: +JS707BB1U5P1 MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 9: Technical Specifications

    Immunity to conducted disturbances inducted by radiofrequency field 0.15 ÷ 80 MHz, 10V EN 61000-4-6 Power frequency magnetic field immunity test Enclosure, 50/60Hz, 30A/m EN 61000-4-8 MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 10 The viewing angles are specified for the horizontal (L,R) and vertical (U,D) axes in reference to the vertical axis of the display. The specified viewing angles above always refer to the standard mounting orientation. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 11 • Dextrose (5% Glucose Solution) • Hydrogen chloride (0.5% Solution PH=1) • Isopropyl Alcohol • Sodium Hypochlorit • Ethyl Alcohol (70%-90%) • Quaternary ammonium compound MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 12 A large number of gloves (rubber gloves, light/heavy leather gloves, disposable latex gloves, etc.) are sup- ported. Due to the variety of commercially available gloves, however, EXOR cannot guarantee all types. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 13: Technical Data

    USB port connector) connector) connector) Battery rechargeable rechargeable rechargeable Real Time Clock Power supply 802.3af 802.3af 802.3at Current consumption Weight 0.7 Kg 1.2 Kg 4.0 Kg MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 14 10/100 PoE 802.3af/at 1 (Host v. 2.0, request special USB port connector) Battery rechargeable Real Time Clock Power supply 802.3bt Current consumption Weight 6.0 Kg MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 15: Dimensions

    4 Technical Data 4.1 Dimensions MODEL JSmart707 131.6mm/5.18” 195.2mm/7.68” 16,5mm/0.64” 17mm/0.66” MODEL JSmart710 183.1mm/7.20” 264.5mm/10.41” 16,5mm/0.64” 17mm/0.66” MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 16 4 Technical Data MODEL JSmart715 248mm/9.76” 398.6mm/15.69” 26,5mm/1.04” 17mm/0.66” MODEL JSmart721 325.6mm/12.81” 534.1mm/21.02” 26,5mm/1.04” 17mm/0.66” MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 17 4 Technical Data Rear view MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 18: Installation Environment And Procedure

    • max surface roughness where the gasket is applied: O120 um Usable cable Max 3mm JSCAxxxx (IP67) Max 10mm Standard Ethernet  CAUTION Tightening torque: 1000Ncm for nut, 130Ncm for screws MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 19: Safety Instruction

    4 Technical Data 4.3 Safety instruction For all installation notes, please refer to the Installation Guide provided with the product. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 20: Connections

    The Ethernet port have two status indicators. Please see description in figure. Green ON: No activity OFF: Valid link has NOT been detected BLINKING: Activity ON: Valid link has been detected MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 21: Power Supply, Grounding And Shielding

    The earth connection can also be made using the screws located near the connector. A label helps identify the ground connection. All the electronic devices in the control system must be properly grounded. Grounding must be performed according to applicable regulations. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 22: Battery

    When the battery is fully charged, it ensures a period of 3 months of date and time back-up at 25°C. Battery Fig. 7.2: JSmart707 Fig. 7.3: JSmart710 MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 23 Dispose of batteries according to local regulations. ATTENTION This device cannot be disposed of as a domestic waste but according to WEEE European Directive 2012/19/EU MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 24: Special Instruction For Use

    Create an Update Package using JMobile Studio and copy it to a USB Flash drive (to transfer via USB, use the dedicated accessory cable). MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 25: System Settings

    Recall context menu and select “System Settings”. To recall the context menu click and hold any unused area of the touchscreen for a few seconds. Default hold time is 2 seconds. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 26 (“user”). Administrator has full access to System Settings (updates of BSP and other system components). Standard user has some limitations. Note: Additional informations on System Settings are available in dedicated manual. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...
  • Page 27: Unpacking And Packing Instructions

    11 Unpacking and Packing Instructions Fig. 11.1: JSmart707, JSmart710 Fig. 11.2: JSmart715, JSmart721 To repack the unit, please follow the instructions backwards. MANUGENJSMART7xxW - Version 1.02 © 2019-2020 EXOR International S.p.A. - Subject to change without notice...