UniOP eTOP Series 500
Operating Instructions
Basic User's Manual for eTOP Series 500
Touchscreen Products
Exor International S.p.A.
MANUGENETOP5xx UniOP
Ver. 1.07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UniOP eTOP 500 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Exor UniOP eTOP 500 Series

  • Page 1 UniOP eTOP Series 500 Operating Instructions Basic User’s Manual for eTOP Series 500 Touchscreen Products Exor International S.p.A. MANUGENETOP5xx UniOP Ver. 1.07...
  • Page 2 Copyright © 2011-2013 Exor International S.p.A. – Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided “as is” without warranty of any kind.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Introduction .............................4 Safety Guide ............................5 1 Product Overview ..........................6 2 Standards and Approvals ........................7 3 Technical Specifi cations ........................8 4 Technical Data ...........................10 4.1 Dimensions .............................14 4.2 Installation Environment .........................16 4.3 Installation Procedure ........................17 5 Connections............................18 5.1 Serial Port ............................20 5.2 Ethernet Port ..........................21...
  • Page 4: Introduction

    Introduction Introduction The operational guidelines described below is information which relates to the device, installation, tran- sportation, storage, assembly, use and maintenance. This Operating Instruction describes the main features of the UniOP operator panels. The Manual refers to the following models: eTOP504 Operator interface with TFT color 4.3”...
  • Page 5: Safety Guide

    Safety Guide Safety Guide The manual contains safety standards that must be respected for the personal safety and to avoid damage. Indications of attention are divided into three levels of severity: DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries. DANGER ATTENTION: indicates a failure to observe safety rules and that defi...
  • Page 6: Product Overview

    Product Overview 1 Product Overview The UniOP eTOP Series 500 HMI products combine state-of-the-art features and top performance with an oustanding design. They are the ideal choice for all demanding HMI applications including factory and building automation. The eTOP Series 500 HMI panels have been designed to run the JMobile software. JMobile runtime included.
  • Page 7: Standards And Approvals

    Standards and Approvals 2 Standards and Approvals The products have been designed for use in an industrial environment in compliance with the 2004/108/ EC EMC Directive. The products have been designed in compliance with: EN 61000-6-4 EN 55011 Class A EN 61000-6-2 EN 61000-4-2 EN 61000-4-3...
  • Page 8: Technical Specifi Cations

    Standards and Approvals 3 Technical Specifi cations Touch screen technology Resistive Back-up battery 3V 50mAh Lithium, rechargeable, not user-replaceable, model VL2330. Fuse Automatic Serial Port RS-232, RS-485, RS-422 software confi gurable User memory Flash 128Mb for eTOP504, 506, 507 Flash 256Mb for eTOP510, 512, 513, 515 Recipe memory Flash Hardware clock...
  • Page 9 100% duration: 1 cycle and 250 cycles (50Hz); 40% duration: 10 cycles (50Hz); duration: 25 cycles (50Hz); Phase: 0°-180° Test executed on the 230Vac side of the Exor International S.p.A. Power Supply EN 61000-4-11 Durability information Backlight service life 40000 Hrs. or more...
  • Page 10: Technical Data

    Technical Data 4 Technical Data Model eTOP504 eTOP506 Display / Backlight TFT Color / LED TFT Color / LED Colors Resolution 480X272 320x240 Diagonal (inches) 4.3” 5.7” Dimming User memory fl ash 128MB 128MB SD card slot Recipe memory Yes. Flash memory storage Yes.
  • Page 11 Technical Data Model eTOP507 eTOP510 Display / Backlight TFT Color / LED TFT Color / LED Colors Resolution 800X480 800x600 Diagonal (inches) 7” widescreen 10.4” Dimming User memory fl ash 128MB 256MB SD card slot Recipe memory Yes. Flash memory storage Yes.
  • Page 12 Technical Data Model eTOP512 eTOP513 Display / Backlight TFT Color / LED TFT Color / LED Colors Resolution 800X600 1280x800 Diagonal (inches) 12.1” 13.3” widescreen Dimming User memory fl ash 256MB 256MB SD card slot Recipe memory Yes. Flash memory storage Yes.
  • Page 13 Technical Data Model eTOP515 Display / Backlight TFT Color / LED Colors Resolution 1024X768 Diagonal (inches) 15” Dimming User memory fl ash 256MB SD card slot Recipe memory Yes. Flash memory storage limited only by available memory Serial Port RS-232,RS-485 RS-422 software confi...
  • Page 14: Dimensions

    Technical Data 4.1 Dimensions Cut out MODEL eTOP504 4mm/0.16” 149mm/5.86” 109mm/4.29” 136mm/5.35” 96mm/3.78” 56mm/2.40” MANUGENETOP5xx UniOP Operating Instructions VER 1.07...
  • Page 15 Technical Data Cut out MODEL eTOP506 4mm/0.16” 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” eTOP507 4mm/0.16” 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” eTOP510 287mm/11.3” 232mm/9.13” 276mm/10.86” 221mm/8.70” 56mm/2.20” 4mm/0.16” eTOP512 336mm/13.22” 267mm/10.51” 326mm/12.83” 256mm/10.07” 56mm/2.20” 4mm/0.16” eTOP513 336mm/13.22” 267mm/10.51” 326mm/12.83” 256mm/10.07” 56mm/2.20” 4mm/0.16” eTOP515 392mm/15.43”...
  • Page 16: Installation Environment

    Technical Data 4.2 Installation Environment The equipment is not intended for continuous exposure to direct sunlight. This might accelerate the aging process of the front panel fi lm. The equipment is not intended for installation in contact with corrosive chemical compounds. Check the resistance of the front panel fi...
  • Page 17: Installation Procedure

    Technical Data 4.3 Installation Procedure Place the fi xing brackets as shown in fi gure (Fig. 4.3). Fig. 4.3 CAUTION Screw each fi xing screw until the bezel corner gets in contact with the panel. MANUGENETOP5xx UniOP Operating Instructions VER 1.07...
  • Page 18: Connections

    Connections 5 Connections eTOP504 Fig. 5.1 1. Serial Port 2. 2x Ethernet Port 3. USB Port 4. Power Supply 5. Expansion slot for Plugin module 6. SD Card Slot MANUGENETOP5xx UniOP Operating Instructions VER 1.07...
  • Page 19 Connections eTOP5xx Fig. 5.2 1. Serial Port 2. 2x Ethernet Port 3. 2x USB Port 4. Power Supply 5. 2x Expansion slot for Plugin module 6. SD Card Slot MANUGENETOP5xx UniOP Operating Instructions VER 1.07...
  • Page 20: Serial Port

    Connections 5.1 Serial Port The serial port is used to communicate with the PLC or with another type of controller. Different electrical standards are available for the signals in the PLC port connector: RS-232, RS-422, RS-485. The serial port is software programmable. Make sure you select the appropriate interface in the programming software.
  • Page 21: Ethernet Port

    Connections 5.2 Ethernet Port The Ethernet port have two status indicators. Please see description in fi gure. OFF: Valid link has NOT been detected ON: No activity ON: Valid link has been detected BLINKING: Activity MANUGENETOP5xx UniOP Operating Instructions VER 1.07...
  • Page 22: Optional Plugin Module

    5.3 Optional plugin module eTOP500 serie panels have several optional plugin module, multiple modules confi gurations are possible. Slot#2 and Slot#4 are available only if plugin module has the “bus extension connector”. Each slot carries three communication channels: • 1 serial interface •...
  • Page 23 Below you can fi nd relation between modules and max number of modules that can be used into eTOP500 serie panels, based on their Interface Type: Module Application Max Modules Interface Type Bus Extension connector PLCM01 1 for eTOP50x 2 for eTOP51x PLCM01-NE 1 for eTOP50x 2 for eTOP51x...
  • Page 24: Power Supply, Grounding And Shielding

    Power Supply, Grounding and Shielding 6 Power Supply, Grounding and Shielding The power supply terminal block is shown in the fi gure below. Fig. 6.1 Note: Ensure that the power supply has enough power capacity for the operation of the equipment. The unit must always be grounded to earth.
  • Page 25: Battery

    Battery 7 Battery These devices are equipped with rechargeable Lithium battery, not user-replaceable. The following information is maintained by the battery: hardware real-time clock (date and time) • Charge: At fi rst installation must be charged for 48 hours. When the battery is fully charged, it ensures a period of 3 months of data back-up at 25°C. Battery Fig.
  • Page 26: Cleaning Faceplates

    Cleaning Faceplates / Getting Started 8 Cleaning Faceplates The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents. 9 Getting Started UniOP 500 series panels must be programmed with the programming software JMobile Studio. To program a panel you will have to connect the panel to a personal computer running JMobile Studio software package;...
  • Page 27: System Settings

    System Settings 10 System Settings The UniOP panels have a system settings tool to allow basic and preliminary settings to the unit. The System settings tool comes in the shape of a rotating menu with navigation buttons at top and bottom to scroll between the available options.
  • Page 28 System Settings “User mode” is the simplest possible interface where a generic user can get access to the basic settings of the panel: Calibrate Touch: allows to calibrate the touch screen interface Network: allows to change the options of the panel on-board network card Time: allows to change the panel RTC options, including...
  • Page 29: Led Indicator On Front Panel

    LED Indicator on Front Panel LED Indicator on Front Panel The table below shows the symbol of the LED indicator dedicated to special functions. MANUGENETOP5xx UniOP Operating Instructions VER 1.07...
  • Page 30: Unpacking And Packing Instructions

    Unpacking and Packing Instructions Unpacking and Packing Instructions to repack the unit, please follow the instructions backwards. MANUGENETOP5xx UniOP Operating Instructions VER 1.07...