The operational guidelines described below is information which relates to the device, installation, tran- sportation, storage, assembly, use and maintenance. This Operating Instruction describes the main features of the Exor operator panels. The Manual refers to the following models: eTOP605 Operator interface with TFT color 5”...
Safety Guide Safety Guide The manual contains safety standards that must be respected for the personal safety and to avoid damage. Indications of attention are divided into three levels of severity: DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries. DANGER ATTENTION: indicates a failure to observe safety rules and that deficiency may cause damage.
Product Overview 1 Product Overview The Exor eTOP Series 600 HMI products combine state-of-the-art features and top performance with an oustanding design. They are the ideal choice for all demanding HMI applications including factory and building automation. The eTOP Series 600 HMI panels have been designed to run the JMobile software.
Standards and Approvals 2 Standards and Approvals The products have been designed for use in an industrial environment in compliance with the 2014/30/ EU EMC Directive. The products have been designed in compliance with: EN 61000-6-4 EN 55011 Class A EN 61000-6-2 EN 61000-4-2 EN 61000-4-3...
Page 8
05/16 serial number 09994847559 version id of the product 091003B03101000 manufacturer address and Exor International S.p.A. read instruction warning Via Monte Fiorino 9 IT-37057 San Giovanni Lupatoto (VR) ATEX Marking DEMKO 16 ATEX 1683X II 3G Ex nA IIC T4 Gc -20<Tamb<+60°C II 3D Ex tc IIIC T105°C Dc...
100% duration: 1 cycle and 250 cycles (50Hz); 40% duration: 10 cycles (50Hz); duration: 25 cycles (50Hz); Phase: 0°-180° Test executed on the 230Vac side of the Exor International S.p.A. Power Supply EN 61000-4-11 Durability information Backlight service life 40000 Hrs. or more...
Technical Data 4 Technical Data Model eTOP605 eTOP607M Display / Backlight TFT Color / LED TFT Color / LED Colors Resolution 800X480 800X480 Diagonal (inches) 5” widescreen 7” widescreen Dimming User memory flash 128MB 256MB SD card slot Yes. Flash memory storage Yes.
Page 11
Technical Data Model eTOP610 Display / Backlight TFT Color / LED Colors Resolution 1280X800 Diagonal (inches) 10.1” widescreen Dimming User memory flash 256MB SD card slot Yes. Flash memory storage Recipe memory limited only by available memory RS-232,RS-485, RS-422 DB9 Serial Port female software configurable 2 10/100 Mbit with integrated...
Technical Data 4.1 Dimensions Cut out MODEL 147mm/5.78” 107mm/4.21” 136mm/5.35” 96mm/3.78” 56mm/2.40” 8mm/0.31” eTOP605 MANUGENETOP6xx Operating Instructions VER 1.03...
Page 13
Technical Data Cut out MODEL 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” 8mm/0.31” eTOP607M 282mm/11.1” 197mm/7.80” 271mm/10.67” 186mm/7.32” 56mm/2.20” 8mm/0.31” eTOP610 MANUGENETOP6xx Operating Instructions VER 1.03...
Technical Data 4.2 Installation Environment Avoid prolonged exposition to direct sunlight to avoid the risk of overheating the device. The equipment is not intended for installation in contact with corrosive chemical compounds. Check the resistance of the front panel to a specific compound before installation. Do not use tools of any kind (screwdrivers, etc.) to operate the touch screen of the panel.
Technical Data 4.3 Safety instruction For all installation notes, please refer to the Installation Guide provided with the product. 4.4 Installation Procedure Place the fixing brackets contained in the fixing kit as shown in figure CAUTION Tightening torque: 130Ncm or screw each fixing screw until the bezel corner gets in contact with the panel.
Connections 5 Connections eTOP605 Fig. 5.1 1. Serial Port 2. 2x Ethernet Port 3. USB Port 4. Power Supply 5. Expansion slot for Plugin module 6. SD Card Slot MANUGENETOP6xx Operating Instructions VER 1.03...
Page 17
Connections eTOP607M and eTOP610 Fig. 5.2 1. Serial Port 2. 2x Ethernet Port 3. USB Port (version 2.0 - 1.1) 4. USB Port (version 2.0 High speed only) 5. Power Supply 6. 2x Expansion slot for Plugin module 7. SD Card Slot MANUGENETOP6xx Operating Instructions VER 1.03...
Connections 5.1 Serial Port The serial port is used to communicate with the PLC or with another type of controller. Different electrical standards are available for the signals in the PLC port connector: RS-232, RS-422, RS-485. The serial port is software programmable. Make sure you select the appropriate interface in the programming software.
5.3 Optional plugin module eTOP600 serie panels have several optional plugin module, multiple modules configurations are possible. Slot#2 and Slot#4 are available only if plugin module has the “bus extension connector”. Each slot carries three communication channels: • 1 serial interface •...
Page 20
05/16 serial number 09994847559 version id of the product 050100A00000000 manufacturer address and Exor International S.p.A. read instruction warning Via Monte Fiorino 9 IT-37057 San Giovanni Lupatoto (VR) ATEX Marking DEMKO 16 ATEX 1683X II 3G Ex nA IIC T4 Gc -20≤Tamb≤+60°C II 3D Ex tc IIIC T105°C Dc...
Page 21
05/16 serial number 09994847559 version id of the product 051201A00001000 manufacturer address and Exor International S.p.A. read instruction warning Via Monte Fiorino 9 IT-37057 San Giovanni Lupatoto (VR) ATEX Marking DEMKO 16 ATEX 1683X II 3G Ex nA IIC T4 Gc 0≤Tamb≤+50°C II 3D Ex tc IIIC T105°C Dc...
Page 22
Below you can find relation between modules and max number of modules that can be used into eTOP600 serie panels, based on their Interface Type: Module Application Max Modules Interface Type Bus Extension connector PLCM02 Serial PLCM03 Serial RS232 Serial PLCM04 Serial RS485 Serial...
Power Supply, Grounding and Shielding 6 Power Supply, Grounding and Shielding The power supply terminal block is shown in the figure below. Fig. 6.1 3 conductor 1,5mmq wire size minimum, minimum temperature conductor rating 105°C. Note: Ensure that the power supply has enough power capacity for the operation of the equipment. The unit must always be grounded to earth with 1,5mmq wire size minimum.
Charge: At first installation must be charged for 48 hours. When the battery is fully charged, it ensures a period of 3 months of data back-up at 25°C. Battery Fig. 7.1: eTOP605 Battery Fig. 7.2: eTOP607M, eTOP610 ATTENTION Dispose of batteries according to local regulations.
Cleaning Faceplates / Getting Started 8 Cleaning Faceplates The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents. 9 Getting Started eTOP Series 600 HMI products must be programmed with the software JMobile Studio. JMobile Stu- dio is a software tool that must be properly installed on a computer running Microsoft Windows.
System Settings 10 System Settings eTOP Series 600 HMI products include a System Settings tool to allow configuration of system options. The user interface of System Settings tool is based on a rotating menu. Use navigation buttons Next/ Back to scroll through the available options. The active item is highlighted on the left side.
Page 28
System Settings Activation of Systems Settings in System Mode: Normal operation If JMobile runtime is not running: Press “System Settings” button on the HMI screen. If JMobile runtime is running: recall context menu, select “System Settings” Select the Restart option then choose the “Configuration OS” option. Note: To recall the context menu click and hold any unused area of the touchscreen for a few seconds.
Page 29
Resize Image Area reserved to authorized technical personnel Download Configuration OS update the Configuration OS module of BSP Download Main OS update the Main OS module of BSP Download Splash Image replace the splash screen image displayed by the device at power- up;...
Unpacking and Packing Instructions Unpacking and Packing Instructions to repack the unit, please follow the instructions backwards. MANUGENETOP6xx Operating Instructions VER 1.03...
Need help?
Do you have a question about the eTOP605 and is the answer not in the manual?
Questions and answers