Wiring - ComfortStar AHU18-M Owner's Manual & Installation Manual

Air-handler air conditioners
Table of Contents

Advertisement

Wiring

BEFORE PERFORMING ANY
ELECTRICAL WORK, READ THESE
REGULATIONS
1. All wiring must comply with local and national
electrical switchs, regulations and must be
installed by a licensed electrician.
2. All electrical connections must be made
according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor
units.
3. If there is a serious safety issue with the power
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
4. Power voltage should be within 90-110% of
rated voltage. Insu cient power supply can
cause malfunction, electrical shock, or re.
5. If connecting power to xed wiring, a surge
protector and main power switch should be
installed.
6. If connecting power to xed wiring, a switch
or circuit breaker that disconnects all poles and
has a contact separation of at least 1/8in (3mm)
must be incorporated in the xed wiring. The
quali ed technician must use an approved
circuit breaker or switch.
7. Only connect the unit to an individual branch
circuit outlet. Do not connect another
appliance to that outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be rmly connected. Loose
wiring can cause the terminal to overheat,
resulting in product malfunction and possible re.
10.
Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts
within the unit.
11.
If the unit has an auxiliary electric heater, it must
be installed at least 1 meter (40in) away from
any combustible materials.
12.
To avoid getting an electric shock, never touch
the electrical components soon after the power
supply has been turned o . After turning o
the power, always wait 10 minutes or more
before you touch the electrical components.
13.
Make sure that you do not cross your
electrical wiring with your signal wiring.
This may cause distortion and
interference.
14.
The unit must be connected to the
main outlet. Normally, the power supply
must have a impedance of 32 ohms.
15.
No other equipment should be
connected to the same power circuit.
16.
Connect the outdoor wires before
connecting the indoor wires.
WARNING
BEFORE PERFORMING ANY
ELECTRICAL OR WIRING WORK,
TURN OFF THE MAIN POWER TO
THE SYSTEM.
NOTE ON AIR SWITCH
When the maximum current of the air
conditioner is more than 16A, an air switch
or leakage protection switch with
protective device shall be used(purchased
seperately) . When the maximum current
of the air conditioner is less than 16A, the
power cord of air conditioner shall be
equipped with plug (purchased seperately) .
Page 37

Advertisement

Table of Contents
loading

Table of Contents