• Functional description of PRxx2 series controllers • Functional description of PRxx1 series controllers • PR Master User manual Due to hardware differences the previous version of CPR i.e. CPR32-SE v2.0 is described in dedicated manual. 2. D ESCRIPTION AND...
3.2 LED indicators According to fig. 3, CPR32-SE v3.0 is equipped with 5 LED indicators and RESET button (S1) on its PCB. RESET button can be used to restart the CPR in the same way as in case of powering device off and then on.
Page 7
CPR32-SE v3.0 User Manual Rev. C.doc 2023-10-10 Fig. 4 CPR32-SE v3.0 and PR402DR/PR411DR controllers supplied with 18VAC Fig. 5 CPR32-SE v3.0 and PRxx1/PRxx2 series controllers supplied with 12VDC 7/15...
CPR32-SE v3.0 network controller. Single RS485 bus creates network (subsystem) including single CPR32-SE v3.0 unit and up to 32 access controllers. For the communication with distant subsystems it is required to use UT-4DR or UT-4 v2.0 communication interface as both enable communication through computer network (LAN or WAN).
By default the next step consists in detection of controllers on RS485 bus which requires selection of Controllers button and then Add button in Networks window. When all opened windows are closed, CPR32-SE device shall be listed in the main window of PR Master software – see fig. 7 Fig.
Page 10
CPR32-SE unit as well as switch the CPR off and on. Menu: Settings->Inputs/Outputs In the window opened by means of this option it is possible to assign functions to CPR32-SE inputs and outputs. Additionally in case of inputs the administrator can define their NO/NC type and in case of outputs their normal/inverted type.
Page 11
CPR32-SE v3.0 User Manual Rev. C.doc 2023-10-10 Table 3 Input functions Function Type Description [00] None Input line is not used. [01] Clear all alarms When the input is activated then all alarms are in CPR monitored cleared in CPR32-NET unit.
Page 12
CPR32-SE v3.0 User Manual Rev. C.doc 2023-10-10 [65] External buzzer The output is dedicated to connection of external speaker in order to signal acoustically following alarms: • firmware memory error – infinite, modulated signal (3 sec. of sound /3 sec. of pause) •...
• After a few seconds the CPR shall restart automatically and switch to normal mode 4.3 Firmware update The latest versions of firmware and Roger ISP software are available at www.roger.pl. In order to update firmware it is necessary to connect the device by means of RS485 bus to communication interface (UT-2USB or RUD-1) and then connect the interface to PC with installed Roger ISP software.
(erratically jumps around screen) and PR Master software reports serial port error. Note: The problem, which is described above is not caused by CPR32-SE but it results from commonly known Windows fault and it cannot be corrected by Roger engineers.
CPR32-SE v3.0 User Manual Rev. C.doc 2023-10-10 6. P RODUCT HISTORY Table 8. Product history Product version Released Description CPR32-SE v.1.0 01/2007 The first commercial version of the product CPR32-SE v.2.0 11/2009 The next hardware version CPR32-SE v.3.0 01/2017 New electronic module based on PR402DR...