13.16 AUTO COMFORT and ECONAVI Operation
•
AUTO COMFORT start condition:
When AUTO COMFORT button is pressed.
o
•
AUTO COMFORT stop conditions:
When AUTO COMFORT button is pressed again.
o
When unit is OFF by OFF/ON button.
o
When unit is OFF when OFF TIMER activates.
o
When unit is OFF by AUTO OFF/ON button at indoor unit.
o
When POWERFUL, QUIET operation activates.
o
When ◄► button is pressed.
o
•
ECONAVI start condition:
When ECONAVI button is pressed.
o
•
ECONAVI stop conditions:
When ECONAVI button is pressed again.
o
When unit is OFF by OFF/ON button.
o
When unit is OFF when OFF TIMER activates.
o
When unit is OFF by AUTO OFF/ON button at indoor unit.
o
When POWERFUL, QUIET operation activates.
o
When ◄► button is pressed.
o
13.16.1 Human Activity Sensor
•
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
•
AUTO COMFORT / ECONAVI initialization
Initialize indication
1
0 – 2 seconds
2
2 – 3 seconds
3
3 – 70 seconds
* □ Indicator ON, ■ Indicator OFF
•
Human activity judgment is as following
Human Activity Sensor
□
■
I
■
II
■
III
■
IV
□
Repeat Step I to IV