WATERPROOF SELF TESTING NON MAINTAINED SPOT LIGHT
EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Ni-MH)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
GENERAL
These devices are used indoors (ta 40 C) in
places where emergency luminaires are
needed. The luminaires GR-290/WP and GR-
292/WP are suitable for corridors lighting and
the GR-291/WP and GR-293/WP for open
a r e a l i g h t i n g . E a c h d e v i c e m u s t b e
permanently connected to mains power
supply. In normal operation the battery is
charging. In case of a mains power supply
failure the device will light the illumination
led automatically in emergency mode. When
the mains power supply is restored the
device turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions οn page 2.
Battery Charging
The battery charging is completely controlled.
In this case, is achieved the perfect battery
maintenance , as well as the elongation of its
duration. When the battery has completely
charged, it charges with a maintenance
current.
Battery Cut-off
The device in this operation when the mains
power supply fails and battery has lost its
Page 1 from 5
GR-290/WP
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products
Olympia Electronics - European manufacturer
o
(for LED MODULE specifications see page 4)
GR-291/WP
220-240V AC / 50-60Hz
3.7W / 4.1 VA
4.8V/1.2Ah
Deep discharge and overcharge protection
Charge, lamp fault, battery fault, TEST button
24 hours
1.5 hour
1 white power LED
270lm
IP65
5 to 40 C
Up to 95%
ABS/PC, PC
Ø125 x 65 mm
430gr.
3 years (1 year for the battery)
energy. During this operation the device
enters the idle state and battery consumption
is negligible, in order to be protected from
deep discharge.
Automatic Operational Test
It is conducted automatically every 15 days. In
order to be performed, the mains power
supply and the battery should be connected.
Automatic Autonomous Test
The Automatic Autonomous Test is conducted
and measures the device's back up operation
and emergency duration. The BATTERY
FAULT LED blinks during the measurement,
indicating this process to the user. This test is
conducted automatically every six months. In
order to be performed, the mains power
supply and the battery should be connected
and fully charged. If the battery is not fully
charged, the test is postponed until the battery
is completely charged. If during this test, the
autonomy is less than the nominal then the
battery fault led turned on continuously and
the battery must be replaced.
Back Up Operation
The autonomous duration of battery during
emergency mode is at least the one that is
GR-292/WP
GR-293/WP
3 hours
160lm
o
923293005_09_004

Advertisement

loading

Summary of Contents for olympia electronics GR-290/WP

  • Page 1 The luminaires GR-290/WP and GR- deep discharge. 292/WP are suitable for corridors lighting and the GR-291/WP and GR-293/WP for open Automatic Operational Test a r e a l i g h t i n g .
  • Page 2: Installation Instructions

    stated list technical The light source contained in this characteristics. During emergency mode, a luminaire shall only be replaced by the light source test is also performed. manufacturer, or his agent, or a similar qualified person. ΑΤΤΕΝΤΙΟΝ!!! NOTE! The light source is non-user 1.
  • Page 3: Surface Mounting

    Mark these two drilled points on the required mounting location, drill the holes and install the supplied plastic plugs. ATTENTION!! Especially for the GR-290/WP and GR-292/WP luminaires installation on the ceiling you must align the base with the indications on the luminaire’s base (Figure 5).
  • Page 4 4. Connect the new battery with the same type (step 2 of the installation instructions) and place it in the position of the old one. 5. Replace the removed parts (step 1 and 4) and power the device. GR-290/WP, GR-292/WP Corridor lighting LAMP BATT.
  • Page 5: Warranty

    Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

This manual is also suitable for:

Gr-291/wpGr-292/wpGr-293/wp