trouble shooting --- electronics
MODEL
113.248440
& 113.2485t
0
PROBLEM
Display does not
change when blade
speed is changed.
Display changes back
and forth between
3000 & 2800 in fpm
function.
Display does not
change when blade
tension is changed.
PROBABLE CAUSE
1. Wrong display
function
selected.
2. Encoder or digital
display defective.
1. Slight variations
in
in blade speed.
1. Wrong display function
selected.
2. Encoder or digital
display defective.
3. Encoder not engaged
with tab on actuator.
Display shows
1
in tension function.
! E 1
Blade too tight.
SUGGESTED
CORRECTIVE
ACTION
- Select FPM function.
- Have electronics
checked by qualified
technician. Repair service available at nearest
Sears store.
- Normal.
- Select
_
function.
- Have electronics
checked by qualified
technician. Repair service available at nearest
Sears store.
- Engage tab of actuator with encoder.
- Normal. Reduce blade tension.