Fault code Fault
Flue extraction duct safety device
A14
intervention
F34
Supply voltage under 170V
F37
Incorrect system water pressure
F39
(Optional) External probe fault
Activation of maximum DELTA T
F41
protection
Sensor control protection activation
F42
A42
F43
Exchanger protection intervention.
A23 - A24 -
A26
F15 - F20 -
F21
PCB parameter fault
F40 - F47 -
F50
F51 - F53
Calibration fault
F56 - A56
Calibration procedure not com-
pleted
F61 - A61
PCB AGC01 fault
A54 - A55 -
PCB AGC01 fault
A63
F67
F68 - A68
BCC Service key error
No communication between PCB
A62
and gas valve
Maximum number of consecutive
A64
Resets exceeded
F66
44
BLUEHELIX TECH RRT 34 C
Possible cause
Fault F07 generated 3 times in the
last 24 hours
Electric mains trouble
Pressure too low
Water pressure switch damaged
blocked or not connected
Probe damaged or wiring shorted
Probe disconnected after activating
the outside temperature mode
Heating sensor damaged
Return sensor damaged
No water circulation in the system
Air in the system
Heating sensor damaged
Return sensor damaged or discon-
nected
No system water circulation
Air in the system
Wrong PCB parameter setting
Incorrect parameters
Electrode damaged or not correctly
positioned.
Poor primary circuit circulation or
over heating?
PCB AGC01 internal error
PCB AGC01 internal error
BCC Service key connected
Error loading BCC Service key file
PCB not connected
Valve damaged Replace valve
Maximum number of consecutive
Resets exceeded
Firmware not loaded successfully
cod. 3541O990 - Rev. 01 - 07/2018
Cure
See fault F07
Check the electrical system
Fill the system
Check the water pressure switch
Check the wiring or replace the sensor
Reconnect the external probe or disable the out-
side temperature mode
Check the correct positioning and operation of
the heating sensor
Check the correct positioning and operation of
the return sensor
Check the circulating pump or system blockage
Vent the system
Check the correct positioning and operation of
the heating sensor
Check the correct positioning and operation of
the return sensor
Check the circulating pump or system blockage
Vent the system
Check the PCB parameter and modify it if neces-
sary
Check parameters and carry out a 100% calibra-
tion
Check the position of the electrode, replace it if
necessary. After replacement, repeat the 100%
calibration
Reset the fault. Open the hot water tap and and
wait for the flame to stop flashing (about 2 min-
utes)
Check the earth connection, to the electrode &
replace the PCB if necessary
Try disconnecting the power supply to the boiler
for 10 seconds and replace the PCB if necessary
Load the parameters
Repeat the loading procedure within 5 minutes
from the boiler power supply and replace the
BCC Service key if necessary
Connect the PCB to the Gas valve
Check the wiring or replace the Gas valve
Disconnect the power supply to the boiler for 60
seconds and then reinstate the boiler
Reload the firmware or replace the PCB