BLUEHELIX TECH RRT 34 C
Replacing the circuit board
1
2
•
Isolate the power supply and close the Gas isolation valve to the boiler.
•
After lowering the PCB housing, lift the cover by pulling the tabs open "2".
•
Remove all the electrical connections
•
Remove the PCB by pulling the tabs open on the side & lifting it out "4".
•
Insert the new PCB and reconnect the electrical connections.
To update the circuit board data, use the "KEY" device, following the instructions attached to the kit.
Electrode replacement or maintenance
•
Isolate the power supply and close the Gas isolation valve to the boiler.
•
Disconnect the white ignition lead from the PCB housing and remove the electrode by undoing the screws "1".
•
Remove the exchanger cover and remove the burner (see fig. 43).
•
Clean the electrode (see fig. 43).
•
Refit the clean or new electrode and secure it with the 2 x screws "1" (ensure the gasket is replaced or not damaged).
•
After securing in place, carefully check the distance between the electrodes (see fig. 43).
•
Refit and secure the burner (see fig. 43) (ensure the burner insulation is not damaged otherwise it must be replaced).
•
Refit and secure the burner cover (see fig. 43) (ensure the burner cover seal is not damaged & less than 5 years old).
•
When installing / replacing the burner a combustion calibration must be carried out (See section 3 calibration pro-
cedure).
EN
4
2
fig. 45
1
fig. 46
cod. 3541O990 - Rev. 01 - 07/2018
3
39