Ferroli BLUEHELIX TECH RRT 34 C Manual page 26

Hide thumbs Also See for BLUEHELIX TECH RRT 34 C:
Table of Contents

Advertisement

Contents Description
b09
Fault 20 status selection
Comfort burner on time (b01=1)
Not implemented (b01=2)
b10
Not implemented (b01=3)
Not implemented (b01=4)
Flowmeter timing (b01=1)
Hot water tank preparation mode (b01=2)
b11
Flowmeter timing (b01=3)
Hot water tank preparation mode (b01=4)
Modulation delta (b01=1)
Priority override - Activation (b01=2)
b12
Modulation delta (b01=3)
Priority override - Activation (b01=4)
Not implemented (b01=1)
Priority override - Deactivation (b01=2)
b13
Not implemented (b01=3)
Priority override - Deactivation (b01=4)
b14
Pump antiblock operation time
Flowmeter type selection (b01=1)
No effect on adjustment (b01=2)
b15
Flowmeter type selection (b01=3)
No effect on adjustment (b01=4)
b16
Fan frequency in standby mode
b17
Summer/Winter symbol
DHW mode activation flow rate (b01=1)
No effect on adjustment (b01=2)
b18
DHW mode activation flow rate (b01=3)
No effect on adjustment (b01=4)
DHW mode deactivation flow rate (b01=1)
No effect on adjustment (b01=2)
b19
DHW mode deactivation flow rate (b01=3)
No effect on adjustment (b01=4)
b20
Flue material selection
b21
PVC flue maximum temperature
b22
CPVC flue maximum temperature
b23
Standard flue shutdown maximum temperature
b24
PVC flue shutdown maximum temperature
b25
CPVC flue shutdown maximum temperature
b26
Flow temperature limit in automatic calibration
Maximum temperature during calibration in DHW
b27
mode
b28
Flowmeter sensitivity factor
b29
Restoring Factory Values
P30
Heating ramp rate
Virtual setpoint min. temperature (b01=1)
Virtual setpoint min. temperature (b01=2)
P31
Virtual setpoint min. temperature (b01=3)
Virtual setpoint min. temperature (b01=4)
P32
Heating standby time
P33
Heating Post-Circulation
26
BLUEHELIX TECH RRT 34 C
Range
0=Deactivated, 1=Enabled (Only for versions with
pressure sensor)
0-40 seconds
--
--
--
0=Deactivated, 1-10=seconds
0=Fixed primary, 1=Linked to setpoint, 2=Ramp
0=Deactivated, 1-10=seconds
0=Fixed primary, 1=Linked to setpoint, 2=Ramp
0-30°C/10
0-255 minutes
0-30°C/10
0-255 minutes
--
0-255 minutes
--
0-255 minutes
0-20 seconds
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
0-100%
0 = Disabled, 1 = Enabled
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0=Standard, 1=PVC, 2=CPVC
60-110°C
60-110°C
60-110°C
60-110°C
60-110°C
25°C ÷ 55°C
75°C ÷ 95°C
0 ÷ 60 (0 = disabled)
Change the value from 0 to 10 by pressing the
"DHW +" button. Confirm by pressing the "heating
+" button.
1-20°C/minute
0=Deactivated, 1-80°C
0=Deactivated, 1-80°C
0=Deactivated, 1-80°C
0=Deactivated, 1-80°C
0-10 minutes
0-255 minutes
cod. 3541O990 - Rev. 01 - 07/2018
Default
0=Deactivated
15 seconds
--
--
--
0=Deactivated
0=Fixed primary
0=Deactivated
0=Fixed primary
0°C/10
30 minutes
0°C/10
30 minutes
--
15 minutes
--
15 minutes
5 seconds
2= Flowmeter (190 imp/
l)
2= Flowmeter (190 imp/
l)
2= Flowmeter (190 imp/
l)
2= Flowmeter (190 imp/
l)
0%
0 = Disabled
25
25
25
25
20
20
20
20
0=Standard
88°C
93°C
100°C
93°C
98°C
25°C
75°C
20
-
4°C/minute
0=Deactivated
0=Deactivated
0=Deactivated
0=Deactivated
4 minutes
15 minutes
EN