Requirements; Water Supply Requirements - True RESIDENTIAL TR36RBFRSGA Install Manual

36 inch built-in bottom freezer
Table of Contents

Advertisement

WATER SUPPLY REQUIREMENT S
The unit comes with 20" (508 mm) of polyethylene
tubing with a 1/4" O.D. push connector for customer
attachment.
Before installing your unit, prepare the water supply
line. Please see plumbing requirements in the
plumbing requirements table.
• Purge the water line prior to final connection to the
unit. This removes any debris present in the line.
• Only connect to a potable water supply!
• Do not connect to a hot water supply!
• Install the water filter before turning on the
water supply to the icemaker. See "Water Filter
Installation" (page 23).
• A copper line is not recommended for this
application.
• Check all water line fittings for leaks.
• Tape the supply line to the floor before moving the
unit into its final installation location.
• In the water connection area (see the rough opening
illustration), tape the water line to the floor.
TEC_TM_151 | REV. E | EN
S I T E P R E P A R A T I O N
FIG. 1.
Water line connection. Fitting included, PEX not included
Water Supply
Flow Rate
Operating Pressure
Incoming Water Temperature
NOTE: DIMENSIONS MAY VARY BY ± 1/8" (3.175 mm)
10/30/2023
Plumbing Requirements
1/4" PEX tubing (1/4" O.D. lines
and fittings not included
NOTE: Copper line is not
recommended
0.5 gpm / 1.89 lpm
30-100 psi (207-689 kPa)
33-100°F (0.6-38°C)
WATER AREA
T R- 3 6 RB F I N S TA L L G U I D E
Page 15 of 56

Advertisement

Table of Contents
loading

Table of Contents