Leveling Information; Installation Tip; Installation Troubleshooting - U-Line Echelon Series Installation Manual

Beverage center with overlay
Hide thumbs Also See for Echelon Series:
Table of Contents

Advertisement

7 Level the Unit

Leveling Information

Note: It is recommended that the unit is level.
1. Use a level to check the levelness of the Beverage
Center from front to back and from side to side. Level
should be placed along top edge and side edge as
shown (see Figure 28).
Figure 28
2. If the Beverage Center
the corners of the unit as necessary (see Figure 29).
Figure 29
3. Check the levelness after each adjustment and repeat
the previous steps until the unit is level. Go on to
8 Install the Unit.

Installation Tip

If the room floor is higher than the floor in the cut-out
opening, adjust the rear feet to achieve a total unit rear
height of 1/8" less than the opening's rear height. Shorten
the unit height in the front by adjusting the front feet.
This allows the unit to be gently tipped into the opening.
Readjust the front feet to level the unit after it is correctly
positioned in the opening.
www.U-LineService.com
2175BEVS/2175BEVOL Beverage Center
1
ULIN_0833_A
®
is not level, adjust the feet on
Turn Foot to Adjust
8 Install the Unit

Installation Troubleshooting

Q:
Problem
The door remains open unless it is pushed closed.
A:
Solution
The hinges should be self-closing when the door is open
approximately 8". If this is not the case, make sure the
closers (at the bottom of the hinge pin) are clean, greased
and installed correctly. Also, re-check leveling from front
to back of the unit and readjust if necessary. Make sure
that pivot plate is installed correctly.