Valve Concepts 3200 Installation, Operation And Maintenance Manual

Pressure / vacuum relief vent w/ pipeaway connection

Advertisement

Quick Links

ISO Registered Company
I. 3000 SERIES DESIGN AND FUNCTION
MODEL
P
V
3100
P
V
3200
P
V
3300
V
3400
P
3500
P
3600
V
3700
P
Models 3100 through 3600 Pressure and /or Vacuum
Vents are used for the normal venting requirements.
Normal venting is defined as venting required
because of operational requirements (i.e. filling and
emptying the tank) or atmospheric changes. Model
3700 Emergency Relief Vent is used to meet venting
required when an abnormal condition, such as an
external fire or such as ruptured internal heating
coils, exist either outside or inside the tank.
All of these devices are sized in accordance with API
Standard 2000. Improperly specified relief vents may
result in structural damage to the tank or system and
can cause severe personal injury or death.
Figure 1 - Pressure Relief
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Model 3200
Pressure / Vacuum Relief Vent
w/ Pipeaway Connection
DESCRIPTION
Vent to Atmosphere
Vent to Header
Top Mounted
Vent to Atmosphere
Vent to Header
Side Mounted
Emergency/Manhole Cover
SECTION I
Figure 1 illustrates the operation of the Pressure
Relief Vent under overpressure conditions. As the
tank pressure increases as a result of product being
pumped into the tank and/or because of thermal
expansion of the product and vapors, the pressure
pallet remains closed until the set pressure of the
vent is reached. When the tank pressure reaches the
pressure setting of the vent, the pressure pallet lifts
allowing the tank pressure to bleed off.
Figure 2 illustrates the operation of the Vacuum
Relief Vent under vacuum conditions. As the tank
pressure decreases as a result of product being
pumped out of the tank and/or because of thermal
contraction of the product and vapors, the vacuum
pallet remains closed until the set vacuum of the
vent is reached. When the tank vacuum reaches the
vacuum setting of the vent, the vacuum pallet lifts
allowing air to be drawn into the tank.
Figure 2 - Vacuum Relief
IOM-3200
10-20

Advertisement

Table of Contents
loading

Summary of Contents for Valve Concepts 3200

  • Page 1 IOM-3200 INSTALLATION, OPERATION AND MAINTENANCE MANUAL 10-20 Model 3200 Pressure / Vacuum Relief Vent w/ Pipeaway Connection SECTION I ISO Registered Company I. 3000 SERIES DESIGN AND FUNCTION MODEL DESCRIPTION Figure 1 illustrates the operation of the Pressure 3100 Vent to Atmosphere Relief Vent under overpressure conditions.
  • Page 2: Safety Warnings

    If be used to fill the annular space of the raised face loading weights were shipped separate from the vent, steel flange. IOM-3200...
  • Page 3 5/8” - 11 2.75” 6” 3/4” - 10 3.00” 8” 3/4” - 10 3.00” 10” 7/8” - 9 3.50” 12” 7/8” - 9 3.50” Blind tapped holes only (Models 3100, 3200, and 3300). Use standard ASME stud length for other holes. IOM-3200...
  • Page 4: Maintenance

    Maintenance should only be done by a Place stiffener plate (20,27) over threaded end of qualified technician. Valve Concepts recommends stem. Set diaphragm (18,25) and diaphragm retainer that all service be performed at the factory or a plate (17,24), over end of stem.
  • Page 5 (40), replace as necessary. Re- 15 ft.-lbs. (20.3 Nm) torque to tighten. secure screen and ring to body with cap screws. See Figure 10. Place pressure and vacuum pallet stem assemblies on the correct seat rings (16). IOM-3200...
  • Page 6: Test Procedure

    (in Note: Valve Concepts acceptance criteria meets or the appropriate units) by the incremental weight per exceeds the requirements of API. API 2521 states unit listed in Table 2.
  • Page 7 All proposed changes will require a new name plate quotation for appropriate Kit Number, Price with appropriate ratings and new product code to and Availability. accommodate the recommended part(s) changes. Figure 3 - View with Lifting brackets IOM-3200...
  • Page 8 Figure 9) ‡ Name Plate (Not Shown) Pallet Weights - Vac ‡ Recommended Spare Part Cap Screws Pallet Guide - Vac Pipe Plug Stem Assy - Vac * Early Models included a lock washer, plain washer and a cotter pin. IOM-3200...
  • Page 9 Pallet - Pres Cable - ATEX Pallet - Vac Pallet Guide - Press Cap Screw Pallet Guide - Vac Stem Assy - Pres Machine Screw Stem Assy - Vac Indicator Housing Figure 7 - Indicators Figure 8 - Atex Cable Connections IOM-3200...
  • Page 10 8” 46” 41” 39” 10” 56” 47” 47” 12” 58” 51” 55” * Quantity 2 per unit. ** Quantity 3 per unit. Figure 10 - Flame Screen ITEM NO. DESCRIPTION Flame / Bug Screen Flame Screen Ring Cap Screws IOM-3200...
  • Page 11 Figure 11 - FRP Vent ITEM NO. DESCRIPTION TFE ROPE LENGTH ITEM NO. DESCRIPTION Stem Assy - Vac Size Item 34 * Body Diaphragm Retainer - Press 2” 21” Cover Pallet Diaphragm - Press ‡ 3” 24” Name Plate (Not shown) Pallet Weights - Press 4”...
  • Page 12 Round 3 Tighten to 100% of target torque. Check flange gap around circumference for uniformity. If the gap is not reasonably uniform, make the appropriate adjustments by selective tightening. IOM-3200...
  • Page 13 This is more likely to occur with aluminum or cast iron materials. Correct Installation Incorrect Installation Full Faced Gasket Spacer and Full Faced Gasket Correct Installation IOM-3200...
  • Page 14 Tied diaphragm regulators with outlet ranges greater than 7 barg (100 psig) should be preset to minimize the risk that improper operation might lead to an outboard leak and a potentially explosive atmosphere. All equipment must only be fitted with manufacturer’s original spare parts. Ensure that only non-sparking tools are used, as per EN 1127-1, Annex A. IOM-3200...
  • Page 15 964, 521, 988, 988-MB, 989 CONTROL VALVES 2296/2296HF SCV-30, SCV-S 8700, 8910, 8920, 8930, 8940 2100, 2199 3100, 3200, 3300, 3400, 3500, 3600, 3700 TANK BLANKETING 1078, 1088, 1100, 1049 5100, 5200, 5400 ,5500 4100, 4200, 4300, 4400, 4500, 4600 MISC 764P/PD, 764-37, 764T Cashco, Inc.

Table of Contents