Post Installation Procedure (Optional) ....................16 Acquiring Single Images Using RVG 142, RVG 5200 and RVG 6200 ........17 Preparing the Acquisition of a Single Image Using RVG 142, RVG 5200 & RVG 6200 ......17 Single Image X-ray Exposure Times ...................... 19 Acquiring Single Image Using RVG 142, RVG 5200 &...
Page 3
Troubleshooting ......................63 Contact Information ......................64 RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 3 ...
The information contained in this guide may be subject to modification without notice, justification or notification to the persons concerned. No part of this guide may be reproduced without the express permission of Carestream Dental LLC. The U.S. Federal law restricts this device to sale by or on the order of a physician.
CAUTION: Alerts you to a condition that might cause serious damage. IMPORTANT: Alerts you to a condition that might cause problems. Note: Emphasizes important information. Tip: Provides extra information and hints. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 5 ...
The RVG sensor is radio-sensitive. The active surface of the RVG sensor is the flat surface marked with #1 or #2 indicating the size of the sensor. (For RVG 142, only one sensor size is available.) The following table summarizes RVG sensor type, size and typical usage:...
Apply the same rules for positioning the RVG sensor in the mouth that you use in classic radiology. You can use different systems for positioning the RVG sensor in the mouth. A starter kit is provided with each RVG sensor (except RVG 142 - positioners can be purchased separately). X-ray Source Compatibility The RVG sensor is compatible with all X-ray sources that meet the current standards of intraoral radiology.
See Pairing RVG Connect Units with a Workstation. RVG sensor is connected to the workstation but an error has occurred. An error message will be displayed in a popup window. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 8 ...
• Blue highlight: Frame in the revue and retake mode. This mode interrupts the automatic acquisition sequence. The retake images are displayed in the Retake Image gallery. Figure 4 FMS Preferences RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 10 ...
Page 11
If you try to change the FMS template after you have finished your image acquisitions you are prompted with a warning that indicates that you risk loosing some of the images. Figure 5 FMS Retake Image Gallery RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 11 ...
Page 12
The FMS retake image gallery (B) only displays the images acquired for the frame highlighted in blue in the FMS template (A). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 12 ...
The Welcome to the RVGDriver Setup Wizard dialog box is displayed: Click Next. The Choose Components dialog box is displayed. IMPORTANT: Do NOT uncheck any boxes that are already checked. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 13 ...
Page 14
Then restart your computer (recommended but not mandatory). Connect the RVG sensor to a USB 2.0 port that is connected directly to the motherboard (generally located on the back of the workstation). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 14 ...
Page 15
The Found New Hardware Wizard is displayed. Click Install the software automatically (Recommended), then click Next. Verify the RVG sensor by running the post installation procedure. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 15 ...
on your desktop to start the RVG 142/5200/6200 Service Tools. The Service Tools home page is displayed. Click Post Installation Procedure then follow the instructions on screen. Activate the relevant license key when prompted. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 16 ...
Cover the RVG sensor with a disposable hygienic sleeve specifically designed for each size of RVG sensor. IMPORTANT: Use a NEW hygienic sleeve for each new patient to prevent cross- contamination. Place the protected RVG sensor in the biteblock of the RVG sensor positioner. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 17 ...
Page 18
Move the X-ray source tube head close to the patient and align it with the tooth of the patient and the RVG sensor. IMPORTANT: Make sure that the tube head is not shaking. Select the X-ray exposure time according to the region of interest and the patient type. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 18 ...
IMPORTANT: These are suggested exposure times and need to be adjusted for your specific X-ray source. For dark images, reduce the exposure time and for grainy images, increase the exposure time. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 19 ...
Use the Favorite function to select which filters are displayed in the Control Panel. Use the Acquisition Default function to automatically apply the selected filter at acquisition time. Import or export filter libraries. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 20 ...
Select an appropriate positioner for the region of interest and the size of the RVG sensor. Cover the RVG sensor with a disposable hygienic sleeve specifically designed for each size of RVG sensor. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 21 ...
Page 22
Move the X-ray source tube head to the patient and align it with the tooth of the patient and the RVG sensor. IMPORTANT: Make sure that the tube head is not shaking. Select the X-ray exposure time according to the region of interest and the patient type. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 22 ...
IMPORTANT: These are suggested exposure times and need to be adjusted for your specific X-ray source. For dark images, reduce the exposure time and for grainy images, increase the exposure time. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 23 ...
Not satisfactory, for example, if the exposure quality indicator is red, retake the X-ray (see Retaking FMS Images with RVG 142, RVG 5200 and RVG 6200). Satisfactory, remove the X-ray source tube head. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 24 ...
Page 25
Use the Favorite function to select which filters are displayed in the Control Panel. • Use the Acquisition Default function to automatically apply the selected filter at acquisition time. • Import or export filter libraries. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 25 ...
To restart the automatic acquisition, click the next empty frame in the acquisition sequence. If you want to set your image adjustments to default, click (A). The CS Adapt Library window appears: RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 26 ...
Page 27
IMPORTANT: Do NOT pull the RVG sensor by its cable when you remove the hygienic protection. Clean and disinfect the RVG sensor after each patient (see the RVG 142, RVG 5200 and RVG 6200 Safety, Regulatory and Technical Specifications User Guide (SM847)). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 27 ...
• Green LED indicates that the RVG Connect unit is connected. Ethernet cable connecting the PoE Injector to the LAN, or an Ethernet hub, or a workstation with two Ethernet cards. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 28 ...
Page 29
After three minutes of inactivity, the RVG Connect unit goes into standby mode. The RVG Connect unit is automatically reactivated when you acquire an image. You can also touch any button to reactivate the RVG Connect unit. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 29 ...
• A short press of the button displays the menu and activates choices you make. 5 USB 2.0 port for the RVG sensor 6 RVG sensor holder indicates that the patient name has not yet been received from the workstation. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 30 ...
Page 31
Once the patient name is received from the workstation, the screen displays the patient name at the top as in this example: 8 Ethernet cable connecting the RVG Connect unit to the PoE Injector (power over Ethernet ). After three minutes of inactivity, the RVG Connect unit goes into standby mode. The RVG Connect unit is automatically reactivated when you acquire an image. You can also touch any button to reactivate the RVG Connect unit. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 31 ...
Manually Assigning Static IP Address. Displays the IPv6 address, prefix, and scope. This is useful if you are using IPv6 without Bonjour. By default, an RVG Connect unit has one IPv6 address (link-local). For an RVG Connect unit with several IPv6 addresses, the information is displayed on several screens. Press the touch sensitive button under to display the next screen. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 32 ...
See Pairing RVG Connect Units with a Workstation. RVG sensor is connected to the workstation but an error has occurred. An error message will be displayed in a popup window. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 33 ...
The Welcome to the RVG Driver Setup Wizard dialog box is displayed. Click Next. The Choose Components dialog box is displayed. IMPORTANT: Do NOT uncheck any boxes that are already checked. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 34 ...
Page 35
Manual workstation configuration with a static IP address using the RVG Service Tools (used when Bonjour is not installed). Assigning IP Addresses to RVG Connect Unit Using RVG Service Tools without Bonjour. Click Install. The Installing dialog box is displayed. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 35 ...
Page 36
When the installation is complete, the Completing the RVG Setup Wizard dialog box is displayed. Click Finish. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 36 ...
Ethernet cable to the side of the arm instead of the top. However, you must leave enough slack in the cable at each moving joint of the arm to allow free movement. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 37 ...
Page 38
IMPORTANT: Leave enough slack in the cable at each moving joint of the arm to allow free movement of the X-ray source. Check that the workstation is connected to the local area network with an ethernet cable. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 38 ...
Manual workstation configuration with a static IP address using the RVG Service Tools; this is used when Bonjour is not installed (see Assigning IP Addresses to RVG Connect Unit Using RVG Service Tools without Bonjour). Alternatively you can manually enter an available IP address directly on the RVG Connect unit (see Manually Assigning Static IP Address). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 39 ...
At first the IP address is not displayed as in the example on the left then after a few moments the IP address is displayed as in the example on the right. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 40 ...
Briefly press the menu button on the side of the RVG Connect unit. above the left touch sensitive button cancels the procedure. Press the right touch sensitive button under When the processing is completed the following information is displayed at the top of the screen. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 41 ...
displayed on the screen. Briefly press the menu button on the side of the RVG Connect unit. above the left touch sensitive button cancels the procedure. Press the right touch sensitive button under The RVG Connect unit automatically restarts. Briefly press the menu button on the side of the RVG Connect unit. The following information is displayed at the top of the screen: RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 42 ...
Press the right touch sensitive button below The RVG Connect unit automatically restarts. Briefly press the menu button on the side of the RVG Connect unit. The manually entered IP address is displayed at the top of the screen. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 43 ...
Under Network Configuration, either: Click Obtain an IP address automatically, then click Apply. Manually enter the IP Address, Subnet Mask, and Default Gateway, then click Apply. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 44 ...
Click Configure. The first page explains how to configure the network of the workstation using Microsoft Windows tools. The second page explains the hardware connections and how to put the RVG Connect unit into IP static mode. The third page allows you to assign a specific IP address to the RVG Connect unit. Follow the instructions on screen. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 45 ...
Allows you to import or export the list as a file. This option is useful for a network manager who wants to manage the list for several workstations. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 46 ...
On the RVG Connect unit, click (A) to confirm that you want to unlock this unit. In the Sensor list, click RVG Connect unit with your workstation. to pair the selected The Sensor list is updated and displays the status Locked on this computer. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 47 ...
Page 48
This indicates that the RVG Connect unit and RVG Sensor are paired with this workstation. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 48 ...
Associating Buttons on RVG Connect Unit with Workstation (Optional) After you have paired an RVG Connect unit with a workstation, you can optionally associate one or two buttons on the RVG Connect unit with that workstation. Press either button or button on the front of the RVG Connect unit for a few seconds to pair the workstation with that button. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 49 ...
Wait for the initialization process to complete. Note: The first time you plug an RVG sensor into the RVG Connect unit, it can take awhile to initialize. The RVG Connect screen displays: indicates that the RVG sensor is initialized. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 50 ...
Cover the RVG sensor with a disposable hygienic sleeve specifically designed for each size of RVG sensor. IMPORTANT: Use a NEW hygienic sleeve for each new patient to prevent cross- contamination. 8. Place the protected RVG sensor in the biteblock of the RVG sensor positioner. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 51 ...
Page 52
IMPORTANT: Always insert the RVG sensor holding it horizontally for the comfort of the patient. 10. Move the X-ray source tube head close to the patient and align it with the tooth of the patient and the RVG sensor. IMPORTANT: Make sure that the tube head is not shaking. 11. Select the X-ray exposure time according to the region of interest and the patient type (see Single Image X-ray Exposure Times). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 52 ...
IMPORTANT: These are suggested exposure times and need to be adjusted for your specific X-ray source. For dark images, reduce the exposure time and for grainy images, increase the exposure time. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 53 ...
Clean and disinfect the RVG sensor after each patient (see the RVG 142, RVG 5200 and RVG 6200 Safety, Regulatory, and Technical Specifications User Guide (SM847)). Use the CS Adapt Library software to manage the brightness/contrast filters. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 54 ...
Page 55
Use the Favorite function to select which filters are displayed in the Control Panel. • Use the Acquisition Default function to automatically apply the selected filter at acquisition time. • Import or export filter libraries. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 55 ...
Select an appropriate positioner for the region of interest and the size of the RVG sensor. Cover the RVG sensor with a disposable hygienic sleeve specifically designed for each size of RVG sensor. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 56 ...
Page 57
IMPORTANT: Make sure that the tube head is not shaking. Select the X-ray exposure time according to the region of interest and the patient type (see FMS Images X-ray Exposure Times). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 57 ...
IMPORTANT: These are suggested exposure times and need to be adjusted for your specific X-ray source. For dark images, reduce the exposure time and for grainy images, increase the exposure time. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 58 ...
Continue acquiring images until the whole FMS template is completed. Check the image and if the quality is: Not satisfactory, for example, if the exposure quality indicator is red, retake the X-ray (see Retaking FMS Images with RVG 142, RVG 5200 and RVG 6200). Satisfactory, remove the X-ray source tube head. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 59 ...
Page 60
Use the Favorite function to select which filters are displayed in the Control Panel. • Use the Acquisition Default function to automatically apply the selected filter at acquisition time. • Import or export filter libraries. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 60 ...
To restart the automatic acquisition, click the next empty frame in the acquisition sequence. If you want to set your image adjustments to default, click (A). The CS Adapt Library window appears: RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 61 ...
Page 62
IMPORTANT: Do NOT pull the RVG sensor by its cable when you remove the hygienic protection. Clean and disinfect the RVG sensor after each patient (see the RVG 142, RVG 5200 and RVG 6200 Safety, Regulatory and Technical Specifications User Guide (SM847)). RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 62 ...
Page 63
Overview). the color of the icon shows the connection status. When the icon is red, an error has occurred and an error message will be displayed in a popup window. RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 63 ...
Page 64
List of Importers for European Union According to MDR 2017/745 Carestream Dental France SAS 4 rue F. Pelloutier, Croissy-Beaubourg, 77435 Marne-la-Vallée Cedex 2, France Carestream Dental Germany GmbH RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 64 ...
Page 65
70327 Stuttgart, Germany Carestream Dental Spain S.L.U. Paseo de la Castellana, 79 Madrid 28046, España Carestream Dental Italy S.r.l. Via Mario Idiojmi 3/3, Assago 20090 (MI), Italia RVG 142, RVG 5200 and RVG 6200 User & Installation Guide 65 ...