  • Page 1 CS 2100 User Guide...
  • Page 2 Notice Congratulations on your purchase of the CS 2100. Thank you for your confidence in our products and we will do all in our power to ensure your complete satisfaction. The User Guide for the CS 2100 includes information on the usage of the equipment.
  • Page 3: Table Of Contents

    CS 2100 Unit Configurations ........
  • Page 4 Cleaning and Disinfecting the CS 2100 ........
  • Page 5: 1-About This Guide

    Alerts you to a condition that might cause serious damage. IMPORTANT Alerts you to a condition that might cause problems. NOTE Emphasizes important information. Provides extra information and hints. WARNING Exposure to ionizing radiation CS 2100 User Guide (SM759)_Ed02 1–1...
  • Page 6 Conventions in this Guide 1–2 About This Guide...
  • Page 7: 2-Cs 2100 System Overview

    Chapter 2 CS 2100 SYSTEM OVERVIEW The CS 2100 is compliant with the requirements of the EEC and international medical standards. The CS 2100 unit has been designed to produce high-quality intraoral radiographies that:  Reveal maximum details with the minimum dose to the patient.
  • Page 8 An extension arm and a scissor arm which is equipped with springs that ensure arm stability. The following figure illustrates the extension arm and the scissor arm. Figure 2–1 CS 2100 - Side View Table 2–1 Extension arm types Extension...
  • Page 9 General Overview The CS 2100 unit is also composed of a remote exposure switch which is an optional accessory. The following CS 2100 unit configurations are provided:  Standard wall-mounted unit  Ceiling-mounted unit. The following mounting options are provided: ...
  • Page 10: Cs 2100 Unit Configurations

    CS 2100 Unit Configurations CS 2100 Unit Configurations Figure 2–2 Standard Wall-Mounted Unit High frequency X-ray generator Wall framework Separate control timer unit X-ray exposure button Scissor arm Rectangular collimator ON/OFF switch with built-in LED Extension arm 2–4 CS 2100 SYSTEM OVERVIEW...
  • Page 11 CS 2100 Unit Configurations Figure 2–3 CS 2100 Unit with Separate Exposure Switch NOTE This configuration is an optional configuration High frequency X-ray generator Wall framework Control timer unit X-ray exposure switch with X-ray exposure button Scissor arm Rectangular collimator...
  • Page 12 CS 2100 Unit Configurations Figure 2–4 Ceiling-Mounted Unit High frequency X-ray generator Ceiling mounted unit containing the main powerboard Control timer unit X-ray exposure switch Scissor arm Rectangular collimator ON/OFF switch with built-in LED Extension arm 2–6 CS 2100 SYSTEM OVERVIEW...
  • Page 13 Unit Mounted on Floor Column High frequency X-ray generator Floor column containing the main powerboard Control timer unit X-ray exposure switch with X-ray exposure button Scissor arm Rectangular collimator ON/OFF switch with built-in LED Extension arm Raiser CS 2100 User Guide (SM759)_Ed02 2–7...
  • Page 14 CS 2100 Unit Configurations Figure 2–6 Unit Mounted on Mobile Base High frequency X-ray generator Mobile stand containing the main powerboard Control timer unit X-ray exposure switch with X-ray exposure button Scissor arm Rectangular collimator ON/OFF switch with LED Handle Foot brake 2–8...
  • Page 15: Control Timer Unit

    - OFF: longest exposure times for films and phosphor plates Warning Selection knob: - Press and hold the knob to activate the exposure time selector. - Rotate the knob to select the exposure time. CS 2100 User Guide (SM759)_Ed02 2–9...
  • Page 16 CS 2100 Unit Configurations 2–10 CS 2100 SYSTEM OVERVIEW...
  • Page 17: 3-Cs 2100 Radiology Process

    Paralleling technique The positioning tool used in the paralleling technique allows you to align the beam and the imaging receptor. An appropriate collimator reduces the dosage by limiting the surface exposure. CS 2100 User Guide (SM759)_Ed02 3–1...
  • Page 18: Bisecting Technique

    When using the bisecting technique, do not use a rectangular collimator. This limits the risk of X-ray beam and image receptor misalignment. 90° Positioning the Imaging Receptor Using the CS 2100, you may create an X-ray image on one of the following imaging receptors:  Conventional silver halide films, such as KODAK dental films. ...
  • Page 19: Exposure Times

    0.250 0.500 CR7400 Adult 0.400 0.500 0.630 0.320 0.400 0.400 0.320 0.400 0.630 Child 0.160 0.200 0.250 0.125 0.160 0.160 0.125 0.160 0.320 CS7600 Adult 0.250 0.320 0.400 0.200 0.250 0.250 0.200 0.250 0.500 CS 2100 User Guide (SM759)_Ed02 3–3...
  • Page 20: Exposure Times For Digital Sensors

    0.160 0.160 0.100 0.100 0.125 0.100 0.125 0.200 Resolution mode TROPHY Child 0.080 0.100 0.125 0.063 0.063 0.080 0.063 0.080 0.125 RVGui High Resolution mode Adult 0.125 0.160 0.160 0.100 0.100 0.125 0.100 0.125 0.200 3–4 CS 2100 RADIOLOGY PROCESS...
  • Page 21: Emitted Doses

    60 kV - 7 mA t (s) D (mGy) t (s) D (mGy) 0.010 0.06 0.200 1.22 0.013 0.08 0.250 1.52 0.016 0.10 0.320 1.95 0.020 0.12 0.400 2.44 0.025 0.15 0.500 3.05 0.032 0.19 0.630 3.84 CS 2100 User Guide (SM759)_Ed02 3–5...
  • Page 22: Film Processing

    Before archiving, do not forget to wash the film correctly and to dry it in a clean place. 3–6 CS 2100 RADIOLOGY PROCESS...
  • Page 23: 4-Acquiring An Image

    This chapter describes the various tasks that you must perform for image acquisition. To acquire an image, you can use conventional films or digital receptors. If necessary, for example after a long inactivity period of the CS 2100 system, we recommend to start with the tube seasoning procedure. For more information, see the Tube Seasoning Procedure.
  • Page 24: Launching The X-Ray

    Launching the X-Ray Launching the X-Ray To launch the X-ray, follow these steps: WARNING Be careful not to be exposed to ionizing radiation 1. Press from the control timer unit or from the X-ray exposure switch. The X-ray emission indicator lights up and a beep is heard. 2.
  • Page 25: 5-User Mode

    Modifying Parameters To modify parameters, follow these steps: 1. Turn to select the parameter to modify. 2. Press on until "EDIT" is displayed and a beep is heard. The parameter value starts blinking. CS 2100 User Guide (SM759)_Ed02 5–1...
  • Page 26: Exiting The User Mode

    Exiting the User Mode 3. Turn to change the parameter value. 4. To validate, press and hold for at least 3 seconds until "COPY" is displayed and a beep is heard. 5. To keep the initial value, press on shortly. "ABOR" is displayed. The system returns to the parameter/program mode.
  • Page 27: Manual Tube Seasoning

    4. Select the following series of parameter settings: 60 kV - 7 mA - 1 s. Launch an X-ray. IMPORTANT If you receive error messages while you carry out the procedures, switch OFF and ON the unit and do all the procedures again. If the error messages persists, contact your representative. CS 2100 User Guide (SM759)_Ed02 5–3...
  • Page 28 Performing a Tube Seasoning 5–4 USER MODE...
  • Page 29: Quick Troubleshooting

    The control unit is defective or Control unit doesn't light up. Call your representative. disconnected. Wait until the I01message is no longer The generator is cooling displayed. No X-ray emission The X-ray exposure button is Call your representative. defective. CS 2100 User Guide (SM759)_Ed02 6–1...
  • Page 30 Quick Troubleshooting Malfunction Possible Cause Action The generator is not Adjust the generator position positioned correctly. The exposure time is too short. Increase the exposure time. The development time is too Increase the development time (See short. the manufacturer’s instructions). The developer is too cold.
  • Page 31: Information Messages

    See the User Mode section. IMPORTANT If you switch OFF the system, the microprocessor does not calculate the cooling time. For safety reasons, it considers that the system has not gone through the cooling cycle. CS 2100 User Guide (SM759)_Ed02 6–3...
  • Page 32: Error Messages

    Error Messages Error Messages The following table lists the error messages and the actions to take. Table 2 Error Messages Error Possible Cause Action Message The radiography control button was released E01 + audible Quickly press on the selection knob before the exposure end.
  • Page 33: Quarterly

    Chapter 7 MAINTENANCE This chapter describes the maintenance tasks you must perform for your CS 2100. Quarterly Generator Check that:  The certification label is legible.  No oil leaks. Mechanical support Check that:  The wall framework is securely attached to the wall.
  • Page 34 Annually We recommend that an electrical, mechanical and dosimetric inspection of the unit be carried out by an authorized service technician provided by your representative. Cleaning and Disinfecting the CS 2100 IMPORTANT You must first clean the system before disinfection.
  • Page 35 Chapter 8 CONTACT INFORMATION Manufacturer’s Address Carestream Health, Inc. 150 Verona Street Rochester, NY 14608, USA Authorized Representatives Authorized Representative in the European Community EC REP TROPHY 4, Rue F. Pelloutier, Croissy-Beaubourg 77435 Marne la Vallée Cedex 2, France Representante no Brasil Carestream do Brasil Comércio e Serviços de Produtos MédicosLtda.
  • Page 36 Authorized Representatives 8–2 CONTACT INFORMATION...