In case of warranty, please contact the dealer or the store where you bought this product. Enjoy your product. * Share your experience and opinion on one of the well- known internet portals. Model: TX-270; Article No. 5117; 10/2023...
Read the user manual. Warning Caution, risk of electric shock. Caution, hot surface Specifications subject to change without notice - please make sure you are using the latest manual available on the manufacturer's website. Model: TX-270; Article No. 5117; 10/2023...
⚫ Make sure that the device is well secured during operation and cannot be tripped over by cables. ⚫ Never use the device after a malfunction, e.g. if the device has been dropped into water or damaged in any other way. Model: TX-270; Article No. 5117; 10/2023...
The micro inverter is not intended for mobile use. Modifications to the micro inverter are generally prohibited. For changes in the environment, you must always consult a qualified electrician. Assembly, installation and electrical connection. Model: TX-270; Article No. 5117; 10/2023...
Disclaimer ⚫ In no event shall Technaxx Deutschland be liable/responsible for any direct, indirect punitive, incidental, special consequential danger, to property or life, improper storage, whatsoever arising out of or connected with the use or misuse of their products.
1x AC connection cable 1x user manual Product overview PV Micro Inverter 800W HMS-800W-2T AC connection to power socket (BC05) 4 Antenna (WiFi) Mounting hole DC connection solar panel (MC4) Ground connection Indicator LED Model: TX-270; Article No. 5117; 10/2023...
Simple electricity meters are often not sufficient. ⚫If necessary, the consent of the landlord is required. ⚫ If you are unsure, please have the local conditions checked, if necessary, or contact your network operator for information. Model: TX-270; Article No. 5117; 10/2023...
The same is true for AC arc fault circuit breakers. They are not evaluated for regenerative power and could be damaged if regenerated with the output of a solar micro inverter. Model: TX-270; Article No. 5117; 10/2023...
(+) is connected to the - pole of the panel, the negative marked cable (-) to the + pole. Make sure that the polarity is correct. Note: When plugging in the DC cables, if the AC cable is already plugged in, the micro Model: TX-270; Article No. 5117; 10/2023...
Others ⚫ For installation in places other than a balcony or fence, you can use screws or glue the back of the unit to a flat surface. Model: TX-270; Article No. 5117; 10/2023...
→ no grid feed DC connection voltage lower 22V Flashing fast green (1s): AC connection & → grid feed DC connection voltage over 22V No LED Flashing/LED off: No DC connection/solar panels → no grid feed connected Model: TX-270; Article No. 5117; 10/2023...
If the above steps do not solve the problem, contact our support or an electrician. The AC connection on the micro inverter cannot be replaced/repaired. If the cable has been damaged, the device should be disposed of. Model: TX-270; Article No. 5117; 10/2023...
AP (WiFi=DTUBI-xxxxxxxx) of the micro inverter. Use the WiFi password on the back of the inverter. Go to O&M page (bottom middle icon ). Click on Network configuration and the APP connects with DTU. Model: TX-270; Article No. 5117; 10/2023...
• Enter account = Login account, username created by app. • Enter password = Password created for app login. Note: You will need to be connected to the Hoymiles DTU WiFi access point by APP for first registration and configuration. Model: TX-270; Article No. 5117; 10/2023...
Mechanical data Ambient temperature range (°C) -40~+65 Storage temperature range (°C) -40~+85 Dimensions (WxHxD) mm 261×180×35,1 Weight (kg) Protection class outdoor (IP67) Cooling Natural circulating air - no fans AC output cable length (cm) Model: TX-270; Article No. 5117; 10/2023...
Iz = In + Ig Iz Permissible current carrying capacity of the line In Rated current of the protective device (circuit breaker) Ig rated current of the power generation system Model: TX-270; Article No. 5117; 10/2023...
German household. In the case of a larger cross-section or a different cable type, the permissible current-carrying capacity is different, so that this must be considered separately, in accordance with DIN VDE 0298-4. Model: TX-270; Article No. 5117; 10/2023...
⚫ Only connect the solar system to a permanently connected socket, never to a multiple socket. ⚫ If you still have older screw fuses installed, it is mandatory to replace them from 16A to the next smaller fuse. Model: TX-270; Article No. 5117; 10/2023...
Inverter 12-year limited product warranty Declaration of Conformity The EU Declaration of Conformity can be requested at the following address: www.technaxx.de/ (in the lower bar "Declaration of Conformity"). Disposal Disposal of the packaging. Sort packaging materials by type upon disposal.
Page 21
Made in China Distributed by: Technaxx Deutschland GmbH & Co. KG Konrad-Zuse-Ring 16-18, 61137 Schöneck, Germany Flexible Solar Balcony Power Plant 600W WIFI TX-270 Model: TX-270; Article No. 5117; 10/2023...
Need help?
Do you have a question about the TX-270 and is the answer not in the manual?
Questions and answers