Technaxx TX-233 User Manual

Flexible solar balcony power plant 600w wifi

Advertisement

Quick Links

Technaxx
* User Manual
®
Flexible Solar Balcony Power Plant 600W WiFi
TX-233
Before using the appliance for the first time, please read the instructions for use and
safety information carefully.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capacities, or by persons lacking in experience or
knowledge, unless they are supervised or instructed on the use of this device by a
person responsible for their safety. Children should be supervised to ensure they do
not play with this device.
Keep this user manual for future reference or product sharing carefully. Do the same
with the original accessories for this product. In case of warranty, please contact the
dealer or the store where you bought this product.
Enjoy your product. * Share your experience and opinion on one of the well-
known internet portals.
1
TX-233; 5050; 03/2023

Advertisement

Table of Contents
loading

Summary of Contents for Technaxx TX-233

  • Page 1 In case of warranty, please contact the dealer or the store where you bought this product. Enjoy your product. * Share your experience and opinion on one of the well- known internet portals. TX-233; 5050; 03/2023...
  • Page 2: Table Of Contents

    Inverter .......... 20 Cable guide ........10 WiFi-Stick (DTU TX-247)....20 Connecting the micro inverter to the AC grid (AC connection) ....11 Declaration of Conformity ....20 Mounting ........... 11 Disposal ..........20 General hints ......... 11 TX-233; 5050; 03/2023...
  • Page 3: Important Notes At The Start

    Read the user manual. Read the user manual Warning Caution, risk of electric shock. Caution, hot surface Specifications subject to change without notice - please make sure you are using the latest manual available on the manufacturer's website. TX-233; 5050; 03/2023...
  • Page 4: Note

     Make sure that the device is well secured during operation and cannot be tripped over by cables.  Never use the device after a malfunction, e.g. if the device has been dropped into water or damaged in any other way. TX-233; 5050; 03/2023...
  • Page 5: Intended Use

    The micro inverter may only be operated with a fixed connection to the public power supply. The micro inverter is not intended for mobile use. Modifications to the micro inverter are generally prohibited. For changes in the environment, you must always consult a qualified electrician. Assembly, installation and electrical connection. TX-233; 5050; 03/2023...
  • Page 6: Assembly, Installation And Electrical Connection

    Disclaimer  In no event shall Technaxx Deutschland be liable/responsible for any direct, indirect punitive, incidental, special consequential danger, to property or life, improper storage, whatsoever arising out of or connected with the use or misuse of their products.
  • Page 7: Features

    1x AC connection cable 36x steel band 1x user manual Product overview PV Micro Inverter 600W TX-204 Betteri socket (input 230V AC) Betteri plug (output 230V AC) Mounting holes Input solar panel (MC4 connector) Ground connection Indicator LED TX-233; 5050; 03/2023...
  • Page 8: Preparation

    Simple electricity meters are often not sufficient. If necessary, the consent of the landlord is required. If you are unsure, please have the local conditions checked, if necessary, or contact  your network operator for information. TX-233; 5050; 03/2023...
  • Page 9: Connecting The Micro Inverter

    The same is true for AC arc fault circuit breakers. They are not evaluated for regenerative power and could be damaged if regenerated with the output of a solar micro inverter. TX-233; 5050; 03/2023...
  • Page 10: Connect The Solar Panels (Dc Connection)

    (+) is connected to the - pole of the panel, the negative marked cable (-) to the + pole. Make sure that the polarity is correct. Note: When plugging in the DC cables, if the AC cable is already plugged in, the micro TX-233; 5050; 03/2023...
  • Page 11: Connecting The Micro Inverter To The Ac Grid (Ac Connection)

     Follow the mounting according balcony mounting – refer to the status give. Use the accessories provided to attach the system to the fence. Others  For installation in places other than a balcony or fence, you can use screws or glue the back of the unit to a flat surface. TX-233; 5050; 03/2023...
  • Page 12: First Commissioning

     no grid feed DC connection voltage lower 22V Flashing fast green (1s): AC connection &  grid feed DC connection voltage over 22V No LED Flashing/LED off: No DC connection/solar panels  no grid feed connected TX-233; 5050; 03/2023...
  • Page 13: Troubleshooting

    If the above steps do not solve the problem, contact our support or an electrician. The AC connection on the micro inverter cannot be replaced/repaired. If the cable has been damaged, the device should be disposed of. TX-233; 5050; 03/2023...
  • Page 14: Wifi-Stick Installation (Dtu Tx-247)

    Get the App To download the App S-Miles Installer from the App-Store or the Google Play Store search for “S-Miles Installer” or scan the QR-code below. [iOS 13.0 or above; Android 10.0 or above (03-2023)] APP icon Android TX-233; 5050; 03/2023...
  • Page 15: Webpage

    Note: You will need to be connected to the Hoymiles DTU WiFi access point by APP for first registration and configuration. If you need further assistance, please contact our support or read detailed TX-247 manual homepage: https://www.technaxx.de/products/ and search for 'TX-247'. TX-233; 5050; 03/2023...
  • Page 16: Technical Specifications

    <50 Mechanical data Ambient temperature range (°C) -40~+65 Storage temperature range (°C) -40~+85 Dimensions (WxHxD) mm 250×170×28 Weight (kg) 3.00 Protection class NEMA outdoor (IP67) Cooling Natural circulating air - no fans AC output cable length (cm) TX-233; 5050; 03/2023...
  • Page 17: Wi-Fi Stick (Dtu Tx-247)

    (circuit breaker in amperes) and the generating equipment (power in amperes). Both Iz and Ig can be found in the following table for the example application below. Iz = In + Ig TX-233; 5050; 03/2023...
  • Page 18: Load Capacity Of Copper Lines

    German household. In the case of a larger cross-section or a different cable type, the permissible current-carrying capacity is different, so that this must be considered separately, in accordance with DIN VDE 0298-4. TX-233; 5050; 03/2023...
  • Page 19: Determination Of The Line Reserve

     Only connect the solar system to a permanently connected socket, never to a multiple socket.  If you still have older screw fuses installed, it is mandatory to replace them from 16A to the next smaller fuse. TX-233; 5050; 03/2023...
  • Page 20: Support

    WiFi-Stick (DTU TX-247) 2-year limited product warranty Declaration of Conformity The EU Declaration of Conformity can be requested at the following address: www.technaxx.de/ (in the lower bar "Declaration of Conformity"). Disposal Disposal of the packaging. Sort packaging materials by type upon disposal.
  • Page 21 Made in China Distributed by: Technaxx Deutschland GmbH & Co. KG Konrad-Zuse-Ring 16-18, 61137 Schöneck, Germany Flexible Solar Balcony Power Plant 600W WIFI TX-233 TX-233; 5050; 03/2023...

Table of Contents