Download Print this page
Graco 24P976 Instructions Manual

Graco 24P976 Instructions Manual

Zone valve kit

Advertisement

Quick Links

Instructions
Zone Valve Kit
Used to control when various zones or sections of a lubrication system receive lubricant.
For professional use only.
Part No.:
24P976 - Zone Valve, 24 VDC, NO
24T296 - Zone Valve, 24 VDC, NC
Maximum Working Pressure: 3500 psi (24.1 MPa, 241 bar)
Important Safety Instructions
Read all warnings and instructions in this
manual and the pump instruction manual
included with your unit. Save all instructions.
NOTICE
All user supplied tubing must be rated for the same
pressure or equipment could be damaged.
Kit Parts:
Ref.
1
2
3
Description
VALVE, zone, 24 VDC, NO
VALVE, zone, 24 VDC, NC
CABLE, 6 ft, vent valve, 2 pin
SCREW, cap, socket
3
24P976
Part No.
Qty.
Part No.
124575
1
-
-
124349
24N402
1
24N402
C19817
2
C19817
332141E
2
1
3
24T296
Qty.
-
-
1
1
2
EN

Advertisement

loading

Summary of Contents for Graco 24P976

  • Page 1 Used to control when various zones or sections of a lubrication system receive lubricant. For professional use only. Part No.: 24P976 - Zone Valve, 24 VDC, NO 24T296 - Zone Valve, 24 VDC, NC Maximum Working Pressure: 3500 psi (24.1 MPa, 241 bar)
  • Page 2: Installation

    Installation Installation Pressure Relief Procedure 3. Connect the pressurized supply line (b) to the inlet fitting (c) of the zone valve (marked “I”). Tighten with wrench. (F . 2) Follow the Pressure Relief Procedure whenever you see this symbol. SKIN INJECTION HAZARD High-pressure fluid from dispense device, hose leaks, or ruptured components will pierce skin.
  • Page 3 Installation Normally Open: Model 24P976 5. Connect the end of the cable (2) to the lube system controller. The valve must receive power to close the zone, pre- venting lubricant from flowing into the lube system 6. Connect cable (2) to the solenoid valve (g). (F .
  • Page 4: Technical Data

    Metric Maximum Operating Pressure 3500 psi 24.1 MPa, 241 bar Temperature Range -40°F to 250°F -40°C to 120°C Output: 24T296 See Performance Chart Output: 24P976 See Performance Chart Voltage 24 VDC Current 0.8 Amp Power 18.2 Watt Inlet/Outlet 1/4 in. npt...
  • Page 5 Dimensions Dimensions inches (mm) NOTE: 24P976 is a normally open valve and is not recommended for use with oil and a pump that outputs less than 1.5 cu. in./min. 3.85 (97.79) Inlet “I” 1/4” npt 2X Ø .281 1.50 Outlet “O”...
  • Page 6: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.