5. Connect the end of the cable (2) to the lube system
controller.
6. Connect cable (2) to the solenoid valve (g). (F
F
. 4
IG
Retrofitting - Existing
Installations
NOTE: These instructions assume grease is already
loaded in the lubrication system
Installation
1. Disconnect power source.
2. Relieve pressure, page 2.
3. Remove existing plumbing installed between pres-
sure supply and lubricator inlet.
4. Continue installation following Assembly Instruc-
tions, Steps 2 - 6, on pages 2 - 3.
332141E
Normally Open: Model 24P976
The valve must receive power to close the zone, pre-
venting lubricant from flowing into the lube system
. 4)
IG
metering device.
Normally Closed: Model 24T296
The valve must receive power to open the zone to allow
lubricant to flow into the lube system metering device.
2
g
Installation