Troubleshooting Guide - EINHELL BG-DW 1300 N Operating Manual

Deep well pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
Anleitung_BG_DW_1300_N_SPK1:_

10. Troubleshooting guide

Faults
The equipment does not start
The equipment does not pump
The equipment does not cut out
Insufficient pumping rate
The equipment switches off after
briefly running
27.06.2008
10:03 Uhr
Cause
- Power supply not connected
- Floating switch does trigger
- Intake sieve clogged
- Discharge hose kinked
- Floating switch cannot sink
- Intake sieve clogged
- Performance reduced due to
heavily contaminated and
abrasive water impurities
- Motor circuit-breaker switches
the equipment off due to
excessive water contamination
- Water temperature too high;
motor circuit-breaker switches
the equipment off
Seite 11
Remedy
- Check power supply
- Raise position of floating switch
- Clean intake sieve with water jet
- Unkink the hose
- Place equipment correctly on
shaft bottom
- Clean intake sieve
- Clean equipment and replace
wear parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum
permissible water temperature
(35 °C) is not exceeded
GB
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

41.709.42

Table of Contents