Step
8.Remove upper cover, horizontal louver, swing board
a.Remove 2 screws at the upper part of
the upper cover and two screws at the
back side of the air-outlet panel.
b.After removing the air-guiding connecting
robe, and then pull the horizontal louver
outwards to remove it.
c.After removing the air swing connection
rod, pull the swing board inwards to
remove it.
9.Remove swing motor and air-guide motor
a.Remove screws used for fixing the air-
guide motor and the remove the air-guide
motor.
b.Remove screws used for fixing the
motor cover, remove the motor cover and
then remove the swing motor.
10.Remove wind board
Remove 11 screws used for fixing the wind
board and then remove the wind board.