Sinclair AST-24BI Service Manual page 47

Hide thumbs Also See for AST-24BI:
Table of Contents

Advertisement

Service Manual
6. Malfunction of Temperature Sensor (F1, F2, F3, F4, F5)
Installation and Maintenance
Troubleshooting for
F1,F2 malfunction
Is
the wiring terminal between the
temperature sensor and the controller
loosened or poorly contacted?
no
Is there short circuit due to trip - over of
the parts?
no
Is the
temperature sensor normal according
to the Resistance
Table?
yes
Replace the mainboard
with the same model.
End
yes
Insert the temperature
sensor tightly
Is malfunction
no
eliminated
yes
Make the parts upright
Is malfunction
no
eliminated
no
Replace it with a
temperature sensor
with the same model
Is malfunction
no
removed
yes
yes
yes
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tower seriesAst-24bi/o

Table of Contents